A4EG

6

Structure and Nomenclature 

Structure

Contact Forms

Operating Patterns

A4EG-C000041

A4EG-BE2R041

A4EG-BM2B041

* Refer to 

Dimensions

 on page 7 for information on the positions of 

pushbutton switches A and B.

 OPEN

ON: CLOSED

 CLOSED

OFF: OPEN

Note: 1.

The contact ON/OFF timing is not synchronized. Confirm 
performance before application.

2.

Direct opening only during grip.

Operating Characteristics

Chart (Enabling Switch Section)

Operating Stroke (Enabling Switch Section)

Operating Force (Enabling Switch Section: 
Reference Values)

* HF: Holding force

Operating Force (Emergency Stop Switch 
Section: Reference Values)

Operating Force (Pushbutton Switch Section: 
Reference Value) 

A4EG-C000041

A4EG-BE2R041
A4EG-BM2B041

Terminal 2

Terminal 1

Terminal 5

Terminal 6

Terminal 3

Terminal 4

Terminal 

8

Terminal 7

Emergency Stop 
S

w

itch Section/

P

u

sh

bu

tton S

w

itch 

Section

Terminal 2

Terminal 1

Terminal 5

Terminal 6

Terminal 3

Terminal 4

Ena

b

ling S

w

itch 

Section

Three Positions: OFF - ON - OFF

Contact Configuration

Position 1

OFF

OFF

N

ot Gripped

Gripped to 
Middle 
Position

Gripped past 
Middle 
Position

Gripped lightly

Released

Released

Gripped Farther

Position 3

Position 2

ON

Ena

b

ling S

w

itch

Emergency Stop S

w

itch

P

u

sh

bu

tton S

w

itch

(5)

(7)

(6)

(

8

)

Terminal 

N

o.

Terminal 

N

o.

Terminal 

N

o.

(5)

(7)

(6)

(

8

)

Terminal 

N

o.

Terminal 

N

o.

(1)

(3)

(5)

(2)

(4)

(6)

Terminal 

N

o.

Terminal 

N

o.

*

*

* Terminal No. (5), (6): A4EG-C000041 only

Operation

Terminal No.

Position 1

Position 2 

Position 3

Enable output

1 to 2

3 to 4

Grip output

5 to 6

Operation

Terminal No.

Position 1

Position 2

Position 3

Enable output

1 to 2

3 to 4

Pushbutton 

switch

Terminal No.

Operation

Contact

Emergency 
stop switch 
output

5 to 6
7 to 8

Operation (push)

ON 

 OFF

Reset (turn reset)

OFF 

 ON

Operation

Terminal No.

Position 1

Position 2

Position 3

Enable output

1 to 2

3 to 4

Pushbutton 

switch

Terminal No.

Operation

Contact

Pushbutton 
switch output

5 to 6

(pushbutton switch A) *

Push

OFF 

 ON

7 to 8

(pushbutton switch B) *

Push

OFF 

 ON

Operating characteristics

Specified value

Enable output (ON)

PT2 max.

3.6 mm

Max. enable holding position 

TT1

Approx. 4.2 mm

Enable direct opening position 

PT3 max.

6.0 mm

Max. stroke

TT2

Approx. 6.7 mm

Operating characteristics

Specified value

Enable operating force

OF1 max.

14 N

Enable holding force

HF *

Approx. 8 N

Grip operating force

OF2 max.

40 N

Operating characteristics

Specified value

Operating force

OF max.

14.7 N

Reset force

RF max.

0.1 N·m

Operating characteristics

Specified value

Operating force 

OF max.

3 N

Operating stroke

PT1

HF

OF1

OF2

PT2

TT1 PT3 PT4 TT2

Oper

ating f

orce

Ena

b

le o

u

tp

u

t

(1-2, 3-4)

Grip o

u

tp

u

t

(5-6)

Summary of Contents for A4EG -

Page 1: ...ld separately provides a versatile method for selecting modes Equipped with conduit connector Ordering Information Enabling Grip Switches Accessories Order Separately Be sure to read the Safety Precautions on page 12 Appearance Contact form Model Enabling switch Monitor switch Pushbutton switch Two contacts 1NC grip output None A4EG C000041 Two contacts None Emergency stop switch 2NC A4EG BE2R041 ...

Page 2: ...2 No 14 E76675 CQC CCC GB 14048 5 Pending approval Item Utilization category AC 15 DC 13 Rated operating current Ie 0 75 A 0 55 A Rated operating voltage Ue 240 V 125 V Item Section Enabling switch Emergency stop switch A4EG BE2R041 only Pushbutton A4EG BM2B041 only Rated insulation voltage 250 V Rated ON current 2 5 A 5 A 0 1 A Rated load 24 VDC 0 3 A inductive load 125 VAC 1 A resistive load EN ...

Page 3: ...ility OFF ON OFF direct opening 100 000 operations min OFF ON 1 000 000 operations min 100 000 operations min set reset for one operation 2 000 000 operations min Dielectric strength Between terminals of the same polarity 2 500 VAC 50 60 Hz 1 minute impulse voltage 1 000 VAC 50 60 Hz 1 minute 1 000 VAC 50 60 Hz 1 minute Between terminals of the different polarity 2 500 VAC 50 60 Hz 1 minute impuls...

Page 4: ...h Emergency Stop Switch Pushbutton Switch 5 7 6 8 Terminal No Terminal No Terminal No 5 7 6 8 Terminal No Terminal No 1 3 5 2 4 6 Terminal No Terminal No Terminal No 5 6 A4EG C000041 only Operation Terminal No Position 1 Position 2 Position 3 Enable output 1 to 2 3 to 4 Grip output 5 to 6 Operation Terminal No Position 1 Position 2 Position 3 Enable output 1 to 2 3 to 4 Pushbutton switch Terminal ...

Page 5: ...red by AVC Corporation of Japan included 48 34 174 60 50 262 38 44 Holding Key Mounted A4EG C000041 Enabling switch Emergency stop switch Conduit connector MG20A P 13B Flexible Super Gland Manufactured by AVC Corporation of Japan included 48 34 50 63 174 191 279 38 44 A4EG BE2R041 Holding Key Mounted Enabling switch Emergency stop switch D4NS order separately A4EG OP3 Holding Key order separately ...

Page 6: ...77 48 34 44 48 34 44 A4EG BM2B041 Holding Key Mounted Enabling switch D4NS order separately A4EG OP3 Holding Key order separately 48 34 174 189 60 292 44 47 6 102 6 76 2 54 2 50 83 2 43 3 235 9 Rubber Cover Replacement Part A4EG OP1 Mounting Bracket for Securing the A4EG A4EG OP2 Mounting surface Two 5 3 dia holes 88 50 82 t3 44 Holding Key A4EG OP3 Enabling Grip Switch Mounted Note The screws are...

Page 7: ...g Grip Switch A4EG Key type Selector Switch A22K Safety Guard Switching Unit G9SX GS Conveyor Emergency Stop Switch Normal Operation Mode Maintenance Mode Door Enabling Grip Switch When pressed processing will stop When the door is opened processing will stop Emergency Stop Switch Door Enabling Grip Switch When pressed processing will stop The Door Switch will be disabled The Enabling Grip Switch ...

Page 8: ...tc Open Open Open Open Open Feedback loop Feedback loop To PLC To PLC G9SX BC202 Control circuit S14 A2 S24 S44 S54 L1 X3 X2 X1 X4 T11 A1 T12 T21 Y1 Y3 T22 T61 T62 M1 M2 T71 Y2 Y4 T72 T31 T32 T33 T41 T42 OFF AND Auto Manual G9SX GS226 T15 Control circuit S3 S7 24 V GND GND Indicator Diagnostic check enabled Indicator Diagnostic check enabled Enabling Grip Switch S4 OPEN S5 KM3 KM4 42 41 12 11 34 3...

Page 9: ... 8 The lower unit will stop when the door is open while in operation mode 9 The door is closed and the lower unit starts again 10 The upper unit and lower unit will stop if the emergency stop is pressed G9SX BC202 Upper Unit Reset switch S2 KM1 KM2 NC contact KM1 KM2 NO contact Logical AND output L1 Logical AND input T41 Emergency stop switch S1 Guard lock safety door switch S4 Enabling grip switc...

Page 10: ...en used and contact reliability for smaller loads may be reduced Do not use the switch in the following locations Locations where the interior of the Protective Door may into direct contact with cutting chips metal filings oil chemicals Locations subject to detergents thinners or other solvents Locations subject to sudden temperature changes Locations subject to high humidity and condensation Loca...

Page 11: ...e The seal performance is reduced when the diameter is smaller than the adequate diameter Use the conforming sizes of lead wires to the apply voltage and current Conforming cable size Recommended multi wire cable size AWG20 to 18 0 5 to 0 75 mm2 Recommended cable diameter 8 0 to 13 mm used with provided Conduit Connector Do not pull the lead wires with excessive force Doing so may disconnect them ...

Page 12: ...EUROPE B V Wegalaan 67 69 NL 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 OMRON CHINA CO LTD Room 2211 Bank of China Tower 200 Yin Cheng Zhong Road Pu Dong New Area Shanghai 200120 China Tel 86 21 5037 2222 Fax 86 21 5037 2200 OMRON S...

Reviews: