Safety Precautions

Be sure to read the precautions for All Pushbutton Switches in the website at:http://www.ia.omron.com/.

Indication and Meaning for Safe Use

Installation Environment

• Do not use the switch in locations where explosive or flammable 

gasses may be present.

• Do not use the switch submerged in oil or water or in locations 

continuously subject to splashes of oil or water. Doing so may 
result in oil or water entering the switch.

Wiring

• Connect a fuse in series with the A22TK to protect it from 

shortcircuit damage. The value of the breaking current of the fuse 
must be calculated by multiplying the rated current by 150% to 
200%.
When using the A22TK for an EN rating, use a 10-A fuse of type gI 
or gG that complies with IEC 60269.

• Always make sure that the power is turned OFF before wiring the 

Switch. 
Also, do not touch the terminals or other current-carrying ports 
while power is being supplied.

• Check the contact specifications before mounting the Switch 

Block. Use an NC contact for a safety circuit. It may not operate 
properly. Check the Switch Block for safe operation before use.

• Check the operating specification before mounting the Operation 

Unit. It may not operate properly. Check the Operation Unit for safe 
operation before use. 

Installation

• Do not drop the Switch. Doing so may prevent the Switch from 

functioning to its full capability.

• Make sure the Switch is mounted securely to prevent it from falling 

off. Otherwise injury may result.

• Mount the Operation Key so that it will not come into contact with 

persons in the area when the door is opened and closed. Injury 
may result.

• Do not use a Switch as a stopper. Otherwise, the switch may be 

damaged and may not operate properly.

• Be sure to use the supplied Lock Ring. Otherwise, the switch may 

rotate and may not operate properly.

Others

• Do not attempt to disassemble or modify the Switch. Doing so may 

cause the Switch to malfunction.

• The durability of the Switch is greatly influenced by the switching 

conditions. Always test the switch under actual working conditions 
before application and use it in a switching circuit for which there 
are no problems with performance.

• The user must not maintain or repair equipment incorporating the 

Switch. Contact the manufacturer of the equipment for any 
maintenance or repairs required.

Indicates an imminently hazardous 
situation which, if not avoided, is likely to 
result in serious injury or may result in 
death. Additionally there may be severe 
property damage.

Indicates a potentially hazardous situation 
which, if not avoided, may result in minor 
or moderate injury or in property damage.

Precautions 
for Safe Use

Supplementary comments on what to do 
or avoid doing, to use the product safely.

Precautions 
for Correct 
Use

Supplementary comments on what to do 
or avoid doing, to prevent failure to 
operate, or undesirable effect on product 
performance.

 DANGER

Always confirm that safety functions are operational 
before stating operation. Wiring mistakes, setting 
mistakes, switch failure or other factors may prevent 
safety functions from operating. This may result in the 
machine continuing to operate, possibly resulting in 
human accidents.

 CAUTION

If the Operation Unit is separated from the Socket Unit, 
the equipment will not stop, creating a hazardous 
condition. 
Secure the lever on the Socket Unit by using the A22Z-
3380 Lock Plate so that the Operation Unit cannot be 
easily separated from the Socket Unit.

(Refer to “Mounting the Lock Plate” at the right.)

[Used in combination with a Slide Key]

The machine may operate, possibly causing injury.
Do not disable safety function by using a spare door 
switch operation key or spare key with the door 
open.

[Used outside/inside hazardous area]

The machine may operate, possibly causing injury.
Do not disable safety function by using a spare key 
outside or inside the hazardous area.

DANGER

CAUTION

Precautions for Safe Use

Summary of Contents for A22TK

Page 1: ...rming maintenance For safety precautions for all pushbutton switches refer to the website at www ia omron com and Safety Precautions on page 12 in this catalog For the most recent information on models that have been certified for safety standards refer to your OMRON website Broad range of applications include use with door locks mode switching and emergency stops when teaching Common Key for Door...

Page 2: ...ped inside Forgetting to remove the key Being trapped inside Assumed risks Starting equipment To Guard Lock Safety door Switch only The safety level is enhanced by switching to maintenance mode However because two different types of keys are required the operator is still at risk of being shut inside if he she forgets to remove the trapped key Guard Lock Safety door Switch Key Selector Switch A22K...

Page 3: ...on Unit Symbol No of notches Key release position Key position of NC contact closing 2LL 2 2RL 2LR 2RR 3 Key Availability Symbol Type None No key K With key 4 Key Type 01 to 30 30 types 2 Contact Configuration Symbol Type 01 SPST NC 11 SPST NO SPST NC 02 DPST NC 12 DPST NC SPST NO 21 DPST NO SPST NC 03 TPST NC Key can be created up to 30 types Specify keys in order starting from 01 Key drop preven...

Page 4: ...s are obtained 2 Key drop preventive type A22TK SJ or A22TK SJ only Key position SPST NC SPST NO SPST NC DPST NC DPST NC SPST NO DPST NO SPST NO TPST NC Key position SPST NC SPST NO SPST NC DPST NC DPST NC SPST NO DPST NO SPST NO TPST NC Operating range Operating range NC contact ON Key Hold NC contact OFF Key Removed NC contact ON Key Hold NC contact OFF Key Removed NC contact OFF Key Hold Key dr...

Page 5: ...21 K01 TPST NC A22TK 2RL 03 K01 SPST NC A22TK 2LR 01 K01 SPST NO SPST NC A22TK 2LR 11 K01 DPST NC A22TK 2LR 02 K01 DPST NC SPST NO A22TK 2LR 12 K01 DPST NO SPST NC A22TK 2LR 21 K01 TPST NC A22TK 2LR 03 K01 SPST NC A22TK 2RR 01 K01 SPST NO SPST NC A22TK 2RR 11 K01 DPST NC A22TK 2RR 02 K01 DPST NC SPST NO A22TK 2RR 12 K01 DPST NO SPST NC A22TK 2RR 21 K01 TPST NC A22TK 2RR 03 K01 SPST NC No A22TK 2LL...

Page 6: ...01 SJ SPST NC A22TK 2RR 01 K01 SJ SPST NO SPST NC A22TK 2RR 11 K01 SJ DPST NC A22TK 2RR 02 K01 SJ DPST NC SPST NO A22TK 2RR 12 K01 SJ DPST NO SPST NC A22TK 2RR 21 K01 SJ TPST NC A22TK 2RR 03 K01 SJ SPST NC No A22TK 2LL 01 01 SJ SPST NO SPST NC A22TK 2LL 11 01 SJ DPST NC A22TK 2LL 02 01 SJ DPST NC SPST NO A22TK 2LL 12 01 SJ DPST NO SPST NC A22TK 2LL 21 01 SJ TPST NC A22TK 2LL 03 01 SJ SPST NC A22TK...

Page 7: ... become rough once they have been used and contact reliability for smaller loads may be reduced Certification body Standards File No UL 1 UL508 C22 2 No 14 E41515 TÜV SÜD EN60947 5 1 certified direct opening mechanism Consult your OMRON representative for details CQC CCC GB14048 5 2003010303070635 KOSHA EN60947 5 1 2009 156 Rated carry current A Rated voltage V Rated current A AC15 inductive load ...

Page 8: ...C SPST NO SPST NC DPST NC DPST NC SPST NO DPST NO SPST NC and TPST NC Switch Lock Plate attached with the Switch Refer to Mounting the Lock Plate on page 13 for use The above figures are examples of the model with key Operation Unit Key 5 9 Lock Plate included A22Z 3380 1 10 9 0 5 34 54 7 16 5 32 6 32 2 30 dia 29 5 dia 27 dia Key 5 9 Lock Plate included A22Z 3380 1 10 9 0 5 30 dia 29 5 dia 27 dia ...

Page 9: ...2 KM1 PLC etc S1 24V Open Feedback loop Emergency Stop Switch Guard lock Safety door Switch G9SX BC202 Unit 1 Control circuit GND Indicator Diagnostic check enabled Indicator Diagnostic check enabled Enabling Switch S4 OPEN S5 KM3 KM4 41 42 11 12 Stop signal Guard Lock release signal S6 UA UB 24V Selector Switch A22TK S8 G9SX BC202 Unit 1 Reset switch S2 KM1 KM2 NC contact KM1 KM2 NO contact KM3 K...

Page 10: ... Safety door Switch D4NL A A A B A C Mechanical Lock Type Enabling Grip Switch A4EG Low speed Monitoring Unit G9SX LM224 F10 R Flexible Safety Unit G9SX BC202 24 VDC S1 Emergency Stop Switch Feedback loop KM1 KM2 T42 T41 T33 T32 T31 Y2 T71 T72 T62 T61 M2 M1 Y1 T22 T21 T12 T11 A1 D22 D21 D12 D11 X4 X3 X2 X1 L1 ES2 ES1 S24 S14 A2 M KM2 KM1 Motor controller Lock release switch S5 E2 E1 41 42 12 11 11...

Page 11: ... 0 24 1 0 4 0 Key Operation Unit Arrow mark Projecting part Mounting ring Rubber washer Panel Lock Ring Move the lever in the direction indicated by the arrow in the following figure then pull the Operation Unit or the Switch Blocks Since the lever has a hole with an inside diameter of 6 5 mm the lever can be moved in the specified direction by inserting a screwdriver into the hole and then moving...

Page 12: ...emble or modify the Switch Doing so may cause the Switch to malfunction The durability of the Switch is greatly influenced by the switching conditions Always test the switch under actual working conditions before application and use it in a switching circuit for which there are no problems with performance The user must not maintain or repair equipment incorporating the Switch Contact the manufact...

Page 13: ...m Single wires stranded wires and crimp terminals can be connected to the Switch Applicable Wiring Materials Twisted strands 2 mm2 max Solid wire 1 6 mm dia max After wiring the Switch maintain an appropriate clearance and creepage distance Do not pull the lead wires with excessive force Doing so may disconnect them The cable cannot be bended repeatedly When bending the cable provide a bending rad...

Page 14: ...visual and operational obtrusions Handle the Switches with care and do not throw or drop them Perform maintenance inspections periodically Do not use the key switch to stop start the machine Mode switching by key must be performed by the operator specified in the operating manual Apply load current not to exceed the rated value The contact ON OFF timing is not synchronized Confirm performance befo...

Page 15: ...ions or uses not described in this document Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems machines and equipment that could present a risk to life or property Please know and observe all prohibitions of use applicable ...

Page 16: ... The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Tokyo JAPAN OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 OMRON CHINA CO LTD Room 2211 Bank of China Tower 200 Yin Cheng Zhong Road PuDong New Area Shanghai 200120 China Tel 86 21 5037 2222 Fax 86 21 5037 2200 OMRON SCIENTIFIC ...

Reviews: