![background image](http://html.mh-extra.com/html/omron/a22tk/a22tk_quick-start-manual_744283007.webp)
A22TK
7
Specifications
Approved Standard Ratings
• UL, cUL (File No. E41515): 6 A at 220 VAC, 10 A at 110 VAC
• TÜV (EN60947-5-1) (Low Voltage Directive): 3 A at 220 VAC
• CCC (GB14048.5): 3 A at 240 VAC, 1.5 A at 24 VDC
Certified Standards
Note: Only models with NC contacts have a direct opening mechanism.
*1. UL-certification for CSA C22.2 No. 14 has been obtained. (Certification has been obtained for the Switch Unit only)
Ratings
Contacts (Standard load)
Note: 1. Rated current values are determined according to the testing conditions. The above ratings were obtained by conducting tests under the
following conditions.
(1) Ambient temperature: 20±2C°
(2) Ambient humidity: 65±5% RH
(3)Operating frequency: 20 operations/minute
2. Minimum applicable load: 10 mA at 5 VDC
Characteristics
*1. Malfunction within 1 ms.
*2. With no icing or condensation.
*3. The degree of protection from the front of the panel.
Note: 1. Do not allow the load current to exceed the rated value.
2. The contact ON/OFF timing is not synchronized. Confirm performance before application.
3. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will
become rough once they have been used and contact reliability for smaller loads may be reduced.
Certification body
Standards
File No.
UL *1
UL508, C22.2 No.14
E41515
TÜV SÜD
EN60947-5-1
(certified direct opening mechanism)
Consult your OMRON
representative for details.
CQC(CCC)
GB14048.5
2003010303070635
KOSHA
EN60947-5-1
2009-156
Rated carry current
(A)
Rated voltage
(V)
Rated current (A)
AC15
(inductive load)
AC12
(resistive load)
DC13
(inductive load)
DC12
(resistive load)
10
24 VAC
10
10
-
-
110
5
10
220
3
6
380
2
3
440
1
2
24 VDC
-
-
1.5
10
110
0.5
2
220
0.2
0.6
380
0.1
0.2
Item
Model
A22TK
Allowable operating
frequency
Mechanical
30 operations/minute max.
Electrical
30 operations/minute max.
Insulation resistance
100 M
Ω
min. (at 500 VDC)
Dielectric strength
Between terminals
of same polarity
2,500 VAC, 50/60 Hz for 1 min.
Between each
terminal and ground
2,500 VAC, 50/60 Hz for 1 min.
Vibration resistance *1
10 to 55 Hz, 1.5-mm double amplitude (within 1 ms)
Shock resistance
Destruction
1000 m/s
2
Malfunction *1
250 m/s
2
max.
Durability
Mechanical
100,000 operations min.
Electrical
100,000 operations min.
Ambient operating temperature *2
-20 to +70°C
Ambient operating humidity
35% to 85%RH
Ambient storage temperature
-40 to +70°C
Degree of protection
IP65 *3
Electric shock protection class
Class II
PTI (tracking characteristic)
175
Degree of contamination
3 (EN60947-5-1)