manualshive.com logo in svg
background image

Information 

Brochure

Choose controls

to match

application

1

Application 

Brochure

Design your 

mechanical 

applications

2

Rough In

Wiring

Rough-in

wiring 

instructions

3

Wiring

Brochure

Wiring and 

installation of 

specific control

4

Data

Brochure

Control settings 

and sequence of 

operation

5

Job

Record

Record settings & 

wiring details for 

future reference

6

D 480 

06/06

tekmarNet

®

4 User Switch 480

- Data Brochure

 

1 of 8 

© 2006 

 D 480 - 06/06

Introduction

The User Switch 480 has 3 programmable buttons that allow users to easily change the operating scene or allow users to 
enable / disable tN4 setpoint devices on a tN4 system.

Multiple User Switches are required if more than 3 scenes or setpoint enable / disables are desired.

The 480 has 3 demand inputs that allow for connection of a tN4 system to a third party automation system or telephone 
switch. This allows users to remotely change the operating scene on a tN4 system.

Features

• 

• 

tN4 Compatible

• 

• 

3 User buttons

• 

• 

3 Demand Inputs

- Input for Home or Building Automation

- Input for Telephone Switch

- Input for Security Systems

User

Button

1

User

Button

2

User

Button

3

Decora cover plate not included

Содержание tekmarNet4 User Switch 480

Страница 1: ...s 3 programmable buttons that allow users to easily change the operating scene or allow users to enable disable tN4 setpoint devices on a tN4 system Multiple User Switches are required if more than 3 scenes or setpoint enable disables are desired The 480 has 3 demand inputs that allow for connection of a tN4 system to a third party automation system or telephone switch This allows users to remotel...

Страница 2: ... 8 Warranty 8 Table of Contents User Interface The User Switch has a total of 5 buttons User Buttons 1 2 and 3 allow for users to select the operation of the tN4 system Buttons A and B allow the installer to program the operation of User Buttons 1 2 and 3 User Button 1 User Button 2 User Button 3 BUTTON A BUTTON B Factory Defaults User Button 1 Scene 1 Label Normal User Button 2 Scene 3 Label Unoc...

Страница 3: ...cial users a simple way to allow staff to override the night setback setup schedule on the tN4 system Current Scene Press the Same Button New Scene Perm Scene 1 No Change Perm Scene 2 Away Selects Scene 1 Perm Scene 3 Unoccupied Selects Scene 1 Perm Scene 4 Selects Scene 1 Perm Scene 5 Selects Scene 1 Tmpy Scene 6 Occupied Selects previous perm scene Tmpy Scene 7 Selects previous perm scene Tmpy S...

Страница 4: ...epeat 5 Times 5 5 Red Off Repeat 6 Times 6 3 hr Temporary Occupied 6 Red Off Repeat 7 Times 7 4 hr Temporary 7 Red Off Repeat 8 Times 8 8 hr Temporary 8 Red Off Repeat User Button 1 User Button 2 User Button 3 STEP 2 Press button A once using a blunt object to begin programming mode Each of the 3 User Buttons will begin to flash to indicate the current program setting Red flashes indicate the User...

Страница 5: ...een Off Repeat STEP 5 Press button B to finalize the User Button setting and exit the programming mode Note To return to Step 2 without saving the setting press button A STEP 6 Repeat steps 2 through 5 to program each User Button User Button 1 User Button 2 User Button 3 PRESS BUTTON B STEP 8 Replace the trim bezel User Button 1 User Button 2 User Button 3 STEP 7 Included with the User Switch are ...

Страница 6: ...efore the user switch responds to further demand inputs For a list of suggested third party devices that can connect to the user switch please contact your tekmar sales representative Application Examples A third party telephone switch has a normally open contact that connects to the User Switch demand 1 input This allows a user to place a telephone call to the telephone switch to change the tN4 s...

Страница 7: ...r correct polarity 1 Button Flashing Red User Button 1 User Button 2 User Button 3 User Button 1 User Button 2 User Button 3 User Button 1 User Button 2 User Button 3 or or The User Button is configured for setpoint device enable operation and there is no response from the tN4 setpoint control Ensure the setpoint device has power and is connected to the tN4 bus Ensure the setpoint device enable nu...

Страница 8: ...ifferent from or in excess of the tekmar Limited Warranty are the Purchaser s sole responsibility and obligation Purchaser shall indem nify and hold tekmar harmless from and against any and all claims liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Purchaser to its customers The pass through Limited Warranty does not appl...

Отзывы: