background image

A22LK

8

Safety Precautions

Be sure to read the precautions 

for All Pushbutton Switches 

in the website at:http://www.ia.omron.com/.

Indication and Meaning for Safe Use

Installation Environment

• Do not use the switch in locations where explosive or flammable 

gasses may be present.

• Do not use the switch submerged in oil or water or in locations 

continuously subject to splashes of oil or water. Doing so may 
result in oil or water entering the switch.

Wiring

• Connect the fuse to the Switch in series to prevent it from short 

circuit damage. The value of the breaking current of the fuse must 
be increased to cover the rated current by 150 to 200%.

• Always make sure that the power is turned OFF before wiring the 

Switch. 
Also, do not touch the terminals or other current-carrying ports 
while power is being supplied. Electric shock may occur.

• Mount the Switch unit in accordance with the specifications of the 

contacts.  Use an NC contact for the safety circuit.  Check the 
safety of operation before use.  The device may fail to operate 
normally.

• Mount the operation unit in accordance with the operation 

specifications.  Check the safety of operation before use.  The 
device may fail to operate normally.

• Be sure to install a protect after the wiring. Do not put the electric 

power when protect is opened.

Installation

• Do not drop the Switch. Doing so may prevent the Switch from 

functioning to its full capability.

• Make sure the Switch is mounted securely to prevent it from falling 

off. Otherwise injury may result.

• Mount the Operation Key so that it will not come into contact with 

persons in the area when the door is opened and closed. Injury 
may result.

• Do not use a Switch as a stopper. Otherwise, the switch may be 

damaged and may not operate properly.

• Be sure to use the supplied Lock Ring. Otherwise, the switch may 

rotate and may not operate properly.

Others

• Do not attempt to disassemble or modify the Switch. Doing so may 

cause the Switch to malfunction.

• The durability of the Switch is greatly influenced by the switching 

conditions. Always test the switch under actual working conditions 
before application and use it in a switching circuit for which there 
are no problems with performance.

• The user must not maintain or repair equipment incorporating the 

Switch. Contact the manufacturer of the equipment for any 
maintenance or repairs required.

Indicates an imminently hazardous 
situation which, if not avoided, is likely to 
result in serious injury or may result in 
death. Additionally there may be severe 
property damage.

Indicates a potentially hazardous situation 
which, if not avoided, may result in minor 
or moderate injury or in property damage.

Precautions 
for Safe Use

Supplementary comments on what to do 
or avoid doing, to use the product safely.

Precautions 
for Correct 

Use

Supplementary comments on what to do 
or avoid doing, to prevent failure to 
operate, or undesirable effect on product 
performance.

 DANGER

Always verify the operation of the safety functions 
before starting the system. Not do so may result that 
the safety functions may not be performed as 
expected if wiring or settings are incorrect or the 
Switch have failed. The controlled system may 
continue to operate and possibly resulting in injury or 
death.

 CAUTION

If the Operation Unit is separated from the Switch Unit, 
the equipment will not stop, creating a hazardous 
condition. 
Secure the lever on the Switch Unit by using the Lock 
pin so that the Operation Unit cannot be easily 
separated from the Switch Unit.

[When the slide key is used]

The machine may start to operate accidentally and 
cause an injury.  Do not disable the device by using 
the spare door Switch operation key or spare key 
while the door is open.

[When the outer-fence Switch or inner-fence 
Switch is used]

The machine may start to operate accidentally and 
cause an injury. Do not disable the inner-fence 
Switch or outer-fence Switch by using the spare 
key.

DANGER

CAUTION

Precautions for Safe Use

Summary of Contents for A22LK Series

Page 1: ...ming maintenance Be sure to read the Safety Precautions on page 8 For the most recent information on models that have been certified for safety standards refer to your OMRON website Broad range of app...

Page 2: ...switch from MAINTENANCE mode to RUN mode after maintenance 8 Exit STOP 1 Remove the key of the A22TK 2 Exit with the key 9 Door locked STOP Close the door and lock the D4SL N 10 Mode changed STOP 1 I...

Page 3: ...lose the door and lock the D4SL N 10 Mode change unlocked STOP 1 Confirm that the door is closed and locked lock monitor of the D4SL N and then enable the A22LK to be unlocked 2 Unlock the A22LK 11 Mo...

Page 4: ...it operation characteristics are obtained 1 2 3 4 A 2 2 L K 2 2 K 0 1 S J 1 Operation Unit Lock and release type are Solenoid lock and Mechanical release Symbol No of notches Key release position Key...

Page 5: ...ability Model 1NC 1NO 1NC 1NO Yes A22LK 2RLA 22 K01 SJ 1NC 1NO 1NC 1NO Yes A22LK 2RLB 22 K01 SJ 1NC 1NO 1NC 1NO No A22LK 2RLA 22 01 SJ 1NC 1NO 1NC 1NO No A22LK 2RLB 22 01 SJ Certification body Standar...

Page 6: ...Unit Lock Pin Attached with the Switch to prevent the operation unit from coming off the switch unit Refer to Lock pin on page 9 for use The above figures are examples of the model with key Key Two k...

Page 7: ...tal travel position Confirm matching of triangle mark Insert the Operation Unit from the front surface of the panel insert the Lock Ring and the mounting ring from the terminal side then tighten the r...

Page 8: ...disassemble or modify the Switch Doing so may cause the Switch to malfunction The durability of the Switch is greatly influenced by the switching conditions Always test the switch under actual workin...

Page 9: ...ting ring The tightening torque is 0 98 to 1 96 N m Lock pin Mount the lock pin to prevent the operation unit from coming off the switch unit Mounting the lock pin 1 Confirm that the lever is on the L...

Page 10: ...ther in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...