A22LK

Operating Environment

• The Switch is intended for indoor use only.
• Do not use the Switch outdoor, or the Switch will malfunction.
• Do not use the Switch in the atmosphere of hazardous gases (H

2

S, 

SO

2

, NH

3

, HNO

3

, CI

2

, etc.) or high temperature and humidity, or it 

will cause the imperfect closing of the contacts or the breakage 
thereof stemming from corrosion.

• Do not use the Switch under any of the conditions mentioned 

below.

• Frequent temperature range.
• High humidity or dew condensation may be generated.
• Where the Switch is subject to severe vibration.
• Where the metal dust, oil, or chemical is sprayed inside the door.
• Where thinner is applied.

Switch unit mounting

• Operation unit can be adjusted to any of the four directions.
• Do not remove the switch unit while energizing. Otherwise the 

machine might mis-operate.

Storage

• Do not store the Switch where corrosive gases (e.g., H

2

S, SO

2

NH

3

, HNO

3

, or Cl

2

) or dust is present, or in locations subject to high 

temperature or high humidity.

Mounting

• Loose screws may result in malfunction.

Be sure to tighten each screw of the Switch properly.

• Do not tighten the mounting ring more than necessary using tools 

such as pointed-nose pliers. Doing so will damage the mounting 
ring. The tightening torque is 0.98 to 1.96 N·m.

Lock pin

• Mount the lock pin to prevent the operation unit from coming off the 

switch unit.

• Mounting the lock pin

(1) Confirm that the lever is on the “LOCK” position and then insert 

the lock pin into the hole of the lever.

(2) Push the lock pin into the protrusion on the switch unit.

Solenoid lock

• It may not be possible to unlock the switch if there is a weight 

placed on the key.
Return the key to FP, HP or TTP when switch is unlocked.

Wiring

• Adequate lead wire size is AWG20 to 18 (0.5 to 0.75mm

2

).

• For the crimp terminal size, refer to the following figure.

• Do not pull a lead wire with excessive force.

Disconnection will be caused.

• Do not bend a cable repeatedly.
• When a cable is bent in connection, the bend radius should be R45 

mm or more so as not to damage the insulation and sheath of the 
cable. A fire and a leakage of current may be caused.

• Apply load current not to exceed the rated value.

Others

• Perform maintenance inspections periodically.
• Do not use the key switch to stop/start the machine.
• Mode switching by key must be performed by the operator 

specified in the operating manual.

Precautions for Correct Use

Switch terminal screw (M3.5)

0.6 to 0.8N

·

m

Solenoid terminal screw (M3)

0.4 to 0.5N

·

m

Protect mounting screw (M3)

0.5 to 0.7N

·

m

Lever

Operation unit

Lock pin

Switch unit

(1)

(2)

For Switch terminal

B: 6.6mm dia.

For Solenoid terminal

B: 5.2mm dia.

Summary of Contents for A22LK Series

Page 1: ...ming maintenance Be sure to read the Safety Precautions on page 8 For the most recent information on models that have been certified for safety standards refer to your OMRON website Broad range of app...

Page 2: ...switch from MAINTENANCE mode to RUN mode after maintenance 8 Exit STOP 1 Remove the key of the A22TK 2 Exit with the key 9 Door locked STOP Close the door and lock the D4SL N 10 Mode changed STOP 1 I...

Page 3: ...lose the door and lock the D4SL N 10 Mode change unlocked STOP 1 Confirm that the door is closed and locked lock monitor of the D4SL N and then enable the A22LK to be unlocked 2 Unlock the A22LK 11 Mo...

Page 4: ...it operation characteristics are obtained 1 2 3 4 A 2 2 L K 2 2 K 0 1 S J 1 Operation Unit Lock and release type are Solenoid lock and Mechanical release Symbol No of notches Key release position Key...

Page 5: ...ability Model 1NC 1NO 1NC 1NO Yes A22LK 2RLA 22 K01 SJ 1NC 1NO 1NC 1NO Yes A22LK 2RLB 22 K01 SJ 1NC 1NO 1NC 1NO No A22LK 2RLA 22 01 SJ 1NC 1NO 1NC 1NO No A22LK 2RLB 22 01 SJ Certification body Standar...

Page 6: ...Unit Lock Pin Attached with the Switch to prevent the operation unit from coming off the switch unit Refer to Lock pin on page 9 for use The above figures are examples of the model with key Key Two k...

Page 7: ...tal travel position Confirm matching of triangle mark Insert the Operation Unit from the front surface of the panel insert the Lock Ring and the mounting ring from the terminal side then tighten the r...

Page 8: ...disassemble or modify the Switch Doing so may cause the Switch to malfunction The durability of the Switch is greatly influenced by the switching conditions Always test the switch under actual workin...

Page 9: ...ting ring The tightening torque is 0 98 to 1 96 N m Lock pin Mount the lock pin to prevent the operation unit from coming off the switch unit Mounting the lock pin 1 Confirm that the lever is on the L...

Page 10: ...ther in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Reviews: