background image

2

Conductive Level Controller

 

61F-GP-N2

Selection Guide for Electrodes, Connecting and Lock Nuts

Application Example

Level control in tanks, reservoirs, sewage plants, underground
wells, mixing plants etc. 

Level control for element protection in pipes, channels, and irriga-
tion systems.

Flow detection in pipes, channels, and irrigation systems.

Ice bank control in cold drink dispensers, ice makers, water chillers,
bulk milk tanks, etc.

Dispensing of liquids by volume.

Indication of liquid buildup due to filter blockages.

Pollution/foul water detection for rivers, drains, etc.

Alarm control warning of abnormal or dangerously high or low lev-
els.

Specifications

*Secondary voltage of transformer

Applicable liquids

Material

Models for individual electrode assembly components

Electrode (1m long)

Connecting nut

Lock nut

Model

Indication 

mark

Model

Inscription

Model

Inscription

Purified city water, 
industrial water, 
sewage

SUS-304 
(AISI-304)

F03-01-SUS304

1 line

F03-02-SUS304

---

F03-03-SUS304

---

Purified city water, 
industrial water, 
sewage, dilute alka-
line solution

SUS316 
(AISI-316)

F03-01-SUS316

2 lines

F03-02-SUS316

6

F03-03-SUS316

6

Supply voltage

24, 110, 120, 220, 230, 240 VAC; 50/60 Hz

Operating voltage range

85% to 110% of rated voltage

Interelectrode voltage

*

8 VAC

Power consumption

Approx. 3.2 VA

Operate resistance

Approx. 4 K

W

 min. Between electrode E1 and E3

Release resistance

Approx. 15 K

W

 max. Between electrode E2 and E3

Response time

Operate: 80 ms max., Release: 160 ms max.

Control output

10 A, 250 VAC (at 40

•

C)

3 A, 250 VAC (at 55

•

C)

Insulation resistance

100 M

W

 max. (at 500 VDC) between power terminals and electrode terminals, and between electrode 

terminals and contact terminals

Dielectric strength

2,000 VAC, 50/60 Hz for 1 min., between power terminals and electrode terminals, and between elec-
trode terminals and contact terminals

Ambient temperature

Operating: –10

•

C to 55

•

C

Ambient humidity

Operating: 45% to 85%

Life expectancy

Mechanical: 10,000,000 operations min.

Weight

Approx. 190 g

Summary of Contents for 61F-GP-N2

Page 1: ...maintenance of electrodes When mounting space is limited Special 3 pole holder of small size and light weight Ideal for soft drink vendors etc where only limited space is avail able For low specific l...

Page 2: ...industrial water sewage SUS 304 AISI 304 F03 01 SUS304 1 line F03 02 SUS304 F03 03 SUS304 Purified city water industrial water sewage dilute alka line solution SUS316 AISI 316 F03 01 SUS316 2 lines F...

Page 3: ...between these probes and the earth probe or tank if it is electrically conductive The water provides a current between the earth probe and the high level probe The output relay in the controller is en...

Page 4: ...hree integral 300 mm length electrodes However a type having 1 000 mm length electrodes is available on request Mounting Holes Rubber packing 11 3 l 7 12 32 38 5 PF1 2 Parallel thread Electrode SUS304...

Page 5: ...ds although they may corrode depending upon the temperature and working conditions Note that the Conductive Level Controller 61F GP N2 is capable of controlling liquids with specific resistances of up...

Page 6: ...nance of the product When fitting crimping terminal s to terminal screw s use a tight ening torque of between 0 45 and 0 6 N m Use power supply of appropriate specifications to provide control source...

Page 7: ...r application or use The following are some examples of applications for which particular attention must be given This is not intended to be an exhaustive list of all possible uses of the products nor...

Page 8: ...rs into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 OMRON Corporation Industrial Automation Company Industrial Devices and Components Division H Q Measuring Components...

Reviews: