SRT1-
j
D08S
SRT1-
j
D08S
55
SRT1-OD08S
100
Cover opening and
closing directions
(75)
2.8
37
Two, 4.2 dia. or M4
Four, M3
7
50
40
92
40
±
0.2
92
±
0.2
Mounting Holes
4
6
Cable Connector for SRT1-OD08S
Applicable conductor size (mm
2
)
Model
0.3 to 0.5
XS8A-0441
0.14 to 0.2
XS8A-0442
0.3 to 0.5
XS8B-0443
XS8B-0443
(Relay Socket )
XS8A-044
j
(Cable Connector)
Plug
connector
Cover
Model number
Pin number
Check window
Calculate the cable conductor size as explained below.
The following information is given on each sensor cable:
Cable dia. (Number of conductors/Conductor dia.)
Conductor size (mm
2
) = (Conductor dia./2)
2
x
π
x Number of conductors
Example: E3S-A
4 dia. (18/0.12)
Conductor size (mm
2
) = (0.12/2)
2
x 3.14 x 18
]
0.20
The conductor size is 0.2 mm
2