![Omron Sentech STC-SBC202POEHS User Manual Download Page 39](http://html1.mh-extra.com/html/omron-sentech/stc-sbc202poehs/stc-sbc202poehs_user-manual_1633588039.webp)
No.12S162-03
39/47
STC-SC202POEHS / SB202POEHS
Users guide
Command No.
Command Description
58H: [7..0]
59H: [15..8]
[Vertical_1 position for the white balance area]
Initial data: 0, data range: 0 to 1,235
Sets the vertical 1 position, which is the vertical start position for the white blance area.
This area is used for the gain calculation of the auto white balance and the push-to-set white balance.
5AH: [7..0]
5BH: [15..8]
[Vertical_2 position for the white balance area]
Initial data: 1,235, data range: 0 to 1,235
Sets the vertical 2 position, which is the vertical end position for the white blance area.
This area is used for calculating the gain of the auto white balance and the push-to-set white balance.
5CH: [7..0]
5DH: [15..8]
[Horizontal_1 position for the white balance area]
Initial data: 0, data range: 0 to 1,623
Sets the horizontal 1 position, which is the vertical end position for the white blance area.
This area is used for calculating the gain of the auto white balance and the push-to-set white balance.
5EH: [7..0]
5FH: [15..8]
[Horizontal_2 position for the white balance area]
Initial data: 1,623, data range: 0 to 1,623
Sets the horizontal 2 position, which is the vertical end position for the white blance area.
This area is used for the calculating the gain of the auto white balance and the push-to-set white balance.
60H: [7..0]
[Camera mode 1] Initial data: 00H
Sets the white balance area ON/OFF and the gamma table ON/OFF.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D5:
No function
Always set at “000”
D4:
White balance area ON/OFF
0: OFF (Full screen)
1: ON (setup area)
D3 to D1:
No function
Always set as “000”
D0:
Gamma table ON/OFF
0: OFF (Gamma=1.0)
1: ON
Aegis Electronic Group, Inc.