![Omron Sentech STC-SBC202POEHS User Manual Download Page 20](http://html1.mh-extra.com/html/omron-sentech/stc-sbc202poehs/stc-sbc202poehs_user-manual_1633588020.webp)
No.12S162-03
20/47
STC-SC202POEHS / SB202POEHS
Users guide
3.4.2
Exposure Timing with the Positive Polarity Trigger Signal
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 60 CLK.
Please input a trigger signal with more than 61 CLK pulse width.
Note 2: The exposure will start 172 CLK after the rising edge of the trigger signal.
3.4.3
Exposure Timing with the Negative Polarity Trigger Signal
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 60 CLK.
Please input a trigger signal with more than 61 CLK pulse width.
Note 2: The exposure will start 172 CLK after the rising edge of the trigger signal.
Input Trigger signal
Exposure time
T1'
SUB
SG
Exposure tim: T1' = Preset exposure time
Filtering *Note.1
60 CLK
Less than
60 useconds
Trigger signal
(With Photocoupler delay
112 CLK
Input Trigger signal
Exposure time
T1'
SUB
SG
Exposure tim: T1' = Preset exposure time
Filtering *Note.1
60 CLK
Less than
15useconds
Trigger signal
(With Photocoupler delay
112 CLK
Aegis Electronic Group, Inc.
For more information please contact Aegis Electronic Group, Inc. *(888)687-6877 *[email protected] *http://www.aegiselect.com