00038076.DOC, Version 1.0
17/21
20
AC input
Plug in the supplied power unit here.
21
ZONE output
Stereo output (RCA, unbal.) for connecting a further
amplifier, e.g. for the monitoring system or PA application
in a secondary room.
22
REC output
Stereo output REC (RCA) for connecting a recording unit.
The recording level is independent of the position of the
output controls MASTER and ZONE.
23
Master output, bal.
Stereo master output (3-pin XLR, bal.) for connecting an
amplifier.
24
Microphone inputs
6.3 mm jacks (bal.) for the microphone channels MIC 2
and MIC 3.
25
Input selector switches
Switches the phono inputs to line inputs.
26
GND (ground terminal)
Ground clamping screw for turntables connected to
channel 2 and channel 3.
27
PHONO inputs
Stereo inputs PHONO (RCA) for channel 2 and channel 3
for connecting turntables with magnetic system.
28
LINE inputs
Stereo inputs LINE (RCA) for channel 1 to 5 for
connecting units with line level outputs (e. g. CD/MP3
player).
29
Master output, unbal.
Stereo master output (RCA, unbal.) for connecting an
amplifier.
30
Cable clamp