background image

Page 16

5) Verify Operation

Verify the module is operational by viewing the LED indicators.

Power 

LED Indicators

Legend

Indicator

Description

Pwr A 

and 

Pwr B

OFF

Unit not powered

Green - ON

Unit powered

Green - Blinking at 1Hz

Unit powered and indicates the Reset switch has been 

depressed for the required length of time causing a restore to 

factory default condition.

Power LED Indicators

NOTE:  The number of power LED indicators will depend on the model of the module.

Uplink Ports 

LED Indicators - SFP and Copper Uplink Models

Legend

Indicator

Description

10 

(100+1000)

OFF

No link

Green - ON

Port linked at 10Mbps

Green - Blinking at 10Hz  Port data activity at 10Mbps
Green - Blinking at 1Hz

Port linked at 10Mbps and in redundant secondary mode

100

OFF

No link

Amber - Blinking at 1Hz

Port linked at 100Mbps and receiving Far End Fault Indicator 

(FEFI)

Green - ON

Port linked at 100Mbps

Green - Blinking at 10Hz  Port data activity at 100Mbps
Green - Blinking at 1Hz

Port linked at 100Mbps and in redundant secondary mode

1000

OFF

No link

Amber - Blinking at 1Hz

Port not linked at 1000Mbps and receiving AN Remote Fault

Green - ON

Port linked at 1000Mbps

Green - Blinking at 10Hz Port data activity at 1000Mbps
Green - Blinking at 1Hz

Port linked at 1000Mbps and in redundant secondary mode

Uplink LED Indicators - SFP and Copper Models

Fiber Ports

LED Indicators - Fixed Fiber Models

Legend

Indicator

Description

1000

OFF

No link

Amber - Blinking at 1Hz

Port not linked at 1000Mbps and receiving AN Remote Fault

Green - ON

Port linked at 1000Mbps

Green - Blinking at 10Hz Port data activity at 1000Mbps
Green - Blinking at 1Hz

Port linked at 1000Mbps and in redundant secondary mode

Fiber LED Indicators - Fixed Fiber Models

Page 15

RJ-45 User Ports 

LED Indicators

Legend

Indicator

Description

10 

(100+1000)

OFF

No link

Amber -ON

Port linked at 10Mbps Half-duplex

Amber - Blinking at 10Hz Port data activity at 10Mbps Half-duplex
Green - ON

Port linked at 10Mbps

Green - Blinking at 10Hz Port data activity at 10Mbps

100

OFF

No link

Amber -ON

Port linked at 100Mbps Half-duplex

Amber - Blinking at 10Hz Port data activity at 100Mbps Half-duplex
Green - ON

Port linked at 100Mbps

Green - Blinking at 10Hz Port data activity at 100Mbps

1000

OFF

No link

Amber -ON

Port linked at 1000Mbps Half-duplex

Amber - Blinking at 10Hz Port data activity at 1000Mbps Half-duplex
Green - ON

Port linked at 1000Mbps

Green - Blinking at 10Hz Port data activity at 1000Mbps

PoE/PSE

OFF

Port PSE inactive

Amber - ON

Port PSE inactive due to power demand exceeding the power 

source

Green - single blink

Powered by 802.3af PoE 15W

Green - two blinks 

Powered by 802.3at PoE 30W

Green - three blinks

Powered by High-Power PoE 60W

Green - four blinks

Powered by High-Power PoE 100W

RJ-45 LED Indicators

NOTE:  The PSE LED may turn Amber (ON) when a non-PD device is connected to the 

port.  
NOTE:  When disconnecting and reconnecting the cable from the RJ-45 PSE ports, it is 

required to wait at least 5 seconds before reconnecting the cable to the RJ-45 PSE port.

Summary of Contents for RuggedNet GHPoE/Si

Page 1: ...aser by registering this product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its option repair or replace a product...

Page 2: ...dNet GHPoE Si and GHPoEBT Si are industrial unmanaged Ethernet switches that feature fiber or copper uplink ports and four 10 100 1000 RJ 45 copper Power over Ethernet user ports The GHPoE Si is a pre...

Page 3: ...d Uplink Redundancy SW4 Reserved SW5 MAC Learning SW6 Forced PoE Power SW7 L2CP SW8 PoE Reset DIP switch Definitions SW1 and SW2 Mode of Operation The modules support Switch Directed Switch and Dual D...

Page 4: ...ary port F2 Directed Switch Mode with Uplink Redundancy Page 8 Dual Device Mode Dual Device Mode is only supported on models with two uplink ports When configured for Dual Device Mode the module is co...

Page 5: ...PD with non standard detection characteristics The DIP switch controls the forced capability for the RJ 45 user ports on the module When this DIP switch is in the LEFT Off position all RJ 45 user port...

Page 6: ...d the GHPoEBT Si 100W models requires 52 to 57VDC inclusive of tolerances 7 31A 56VDC max rated power See specification table for specific model requirements Appropriate overloading protection should...

Page 7: ...into the SFP receptacle on the front of the module see the SFP Data Sheet 091 17000 001 for supported Gigabit transceivers NOTE The release latch of the SFP fiber transceiver must be in the closed up...

Page 8: ...on 1000 OFF No link Amber Blinking at 1Hz Port not linked at 1000Mbps and receiving AN Remote Fault Green ON Port linked at 1000Mbps Green Blinking at 10Hz Port data activity at 1000Mbps Green Blinkin...

Page 9: ...warranty with 24 7 365 free Technical Support Page 18 Page 17 Description RuggedNet GHPoEBT Si 60 100W BT 10 100 1000BASE T with Gigabit Fiber or Copper Uplinks Ruggedized Unmanaged IEEE 802 3bt PoE...

Page 10: ...kV Air 8 kV IEC 61000 4 3 RS 80 MHz to 1 GHz 10V m IEC 61000 4 4 EFT Power 2 kV Signal 1 kV IEC 61000 4 5 Surge Power 2 kV Signal 1 kV IEC 61000 4 6 CS Signal 10 V IEC 61000 4 8 Magnetic Field IEC 610...

Reviews: