background image

Regulatory Compliances

Safety: 

UL 60950-1,  

UL-62368-1,  

IEC 60950-1:2005+A1 :2009,  

IEC 62368:2014/A11:2017,  

EN 60950-1: 2006+A11:2009+A1:2010+A12:2011 

+A2:2013,  

CAN/CSA C22.2 No. 60950-1,  

CAN/CSA C22.2 No. 62368-1-14,  

CE Mark

EMC: 

EN 55032/EN 55024 CE Emissions/Immunity,  

IEC 61000-6-4 Industrial Emissions,  

IEC 61000-6-2 Industrial Immunity

EMI: 

CISPR 32,  

FCC 47 Part 15 Subpart B Class A

EMS: 

IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV,  

IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10V/m,  

IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV,  

IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV,  

IEC 61000-4-6 CS: Signal: 10 V,  

IEC 61000-4-8 (Magnetic Field),  

IEC 61000-4-11 (General Immunity in Industrial 

Environments )

IP Rating: 

IP40 Protection

Customer Support Information

If you encounter problems while installing this product, contact Omnitron Technical 

Support:

Phone:   

(949) 250-6510

Fax: 

 

(949) 250-6514

Address:  

Omnitron Systems Technology, Inc.

  38 

Tesla

 

 

Irvine, CA 92618, USA

Email:  

[email protected]

URL:  

www.omnitron-systems.com

040-03200-001CD   7/20

Page 20

Page 19

Summary of Contents for RuggedNet GHPoE/Si

Page 1: ...aser by registering this product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its option repair or replace a product...

Page 2: ...dNet GHPoE Si and GHPoEBT Si are industrial unmanaged Ethernet switches that feature fiber or copper uplink ports and four 10 100 1000 RJ 45 copper Power over Ethernet user ports The GHPoE Si is a pre...

Page 3: ...d Uplink Redundancy SW4 Reserved SW5 MAC Learning SW6 Forced PoE Power SW7 L2CP SW8 PoE Reset DIP switch Definitions SW1 and SW2 Mode of Operation The modules support Switch Directed Switch and Dual D...

Page 4: ...ary port F2 Directed Switch Mode with Uplink Redundancy Page 8 Dual Device Mode Dual Device Mode is only supported on models with two uplink ports When configured for Dual Device Mode the module is co...

Page 5: ...PD with non standard detection characteristics The DIP switch controls the forced capability for the RJ 45 user ports on the module When this DIP switch is in the LEFT Off position all RJ 45 user port...

Page 6: ...d the GHPoEBT Si 100W models requires 52 to 57VDC inclusive of tolerances 7 31A 56VDC max rated power See specification table for specific model requirements Appropriate overloading protection should...

Page 7: ...into the SFP receptacle on the front of the module see the SFP Data Sheet 091 17000 001 for supported Gigabit transceivers NOTE The release latch of the SFP fiber transceiver must be in the closed up...

Page 8: ...on 1000 OFF No link Amber Blinking at 1Hz Port not linked at 1000Mbps and receiving AN Remote Fault Green ON Port linked at 1000Mbps Green Blinking at 10Hz Port data activity at 1000Mbps Green Blinkin...

Page 9: ...warranty with 24 7 365 free Technical Support Page 18 Page 17 Description RuggedNet GHPoEBT Si 60 100W BT 10 100 1000BASE T with Gigabit Fiber or Copper Uplinks Ruggedized Unmanaged IEEE 802 3bt PoE...

Page 10: ...kV Air 8 kV IEC 61000 4 3 RS 80 MHz to 1 GHz 10V m IEC 61000 4 4 EFT Power 2 kV Signal 1 kV IEC 61000 4 5 Surge Power 2 kV Signal 1 kV IEC 61000 4 6 CS Signal 10 V IEC 61000 4 8 Magnetic Field IEC 610...

Reviews: