2) Installing the Module

The module can be wall or rack mounted using the optional Wall Mount Plate 

(8260-3).  Refer to the Wall Mount Plate user manual (040-08260-301x) for the 

proper installation guidelines.

Wall Mounting

The wall mounting height of the module should be less than or equal to 2 meters 

(6.6 feet) from the floor.  Use the four mounting holes on the module to secure the 

module to the wall.  The module can accommodate #6 screws (not included).

Installation of the module should be such that the air flow in the front, back, side 

and top vents of the switch are not compromised or restricted.
The accessory cables should have their own strain relief and do not pull down on 

the module. 

Rack Mounting

The module can be rack mounted using the optional Rack Mount Shelf (8260-0).  

Refer to the Rack Mount Shelf user manual (040-08260-001x) for the proper 

installation guidelines.
Follow the same guidelines above when rack mounting the module.

3) Apply DC Power

This module is intended for installation in restricted access areas. (“Les matériels 

sont destinés à être installés dans des EMPLACEMENTS À ACCÈS RESTREINT”). 

A restricted access area can be accessed only through the use of a special key, or 

other means of security.
The over current protection for connection with centralized DC shall be provided in 

the building installation, and shall be a UL listed circuit breaker rated 20 Amps, and 

installed per the National Electrical Code, ANSI/NFPA-70.
The GHPoE/Si and GHPoEBT/Si (60W models) re50 to +57VDC inclusive 

of tolerances (4.46A @ 56VDC max rated power) and the GHPoEBT/Si (100W 

models) re52 to +57VDC inclusive of tolerances (7.31A @ 56VDC max 

rated power). See specification table for specific model requirements. 

Appropriate overloading protection should be provided on the DC power source 

outlets utilized.

Top View with DC Power Connector

WARNING:

Only a DC power source that complies with

safety extra low voltage (SELV) requirements can be
connected to the DC-input power supply.

WARNING REGARDING EARTHING GROUND:

o

o

o

o

This equipment shall be connected to the DC supply

system earthing electrode conductor or to a bonding
jumper from an earthing terminal bar or bus to which the
DC supply system earthing electrode is connected.

This equipment shall be located in the same immediate

area (such as adjacent cabinets) as any other equipment
that has a connection between the earthed conductor of
the same DC supply circuit and the earthing conductor,
and also the point of earthing of the DC system. The DC
system shall not be earthed elsewhere.

The DC supply source is to be located within the same

premises as this equipment.

There shall be no switching or disconnecting devices in

the earthed circuit conductor between the DC source and
the earthing electrode conductor.

Locate the DC circuit breaker of the external power source, and switch the circuit 

breaker to the OFF position.
Prepare a power cable using a three conductor insulated wire (not supplied) with 

12AWG to 14AWG thickness.  Cut the power cable to the length required.
Strip approximately 3/8 of an inch of insulation from the power cable wires.
Connect the ground wire to the grounding screws on the back of the module.

Ground Screw Location

Connect the power cables to the module by fastening the stripped ends to the DC 

power connector.

Power Connections

Summary of Contents for RuggedNet GHPoE/Si

Page 1: ...aser by registering this product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its option repair or replace a product...

Page 2: ...dNet GHPoE Si and GHPoEBT Si are industrial unmanaged Ethernet switches that feature fiber or copper uplink ports and four 10 100 1000 RJ 45 copper Power over Ethernet user ports The GHPoE Si is a pre...

Page 3: ...d Uplink Redundancy SW4 Reserved SW5 MAC Learning SW6 Forced PoE Power SW7 L2CP SW8 PoE Reset DIP switch Definitions SW1 and SW2 Mode of Operation The modules support Switch Directed Switch and Dual D...

Page 4: ...ary port F2 Directed Switch Mode with Uplink Redundancy Page 8 Dual Device Mode Dual Device Mode is only supported on models with two uplink ports When configured for Dual Device Mode the module is co...

Page 5: ...PD with non standard detection characteristics The DIP switch controls the forced capability for the RJ 45 user ports on the module When this DIP switch is in the LEFT Off position all RJ 45 user port...

Page 6: ...d the GHPoEBT Si 100W models requires 52 to 57VDC inclusive of tolerances 7 31A 56VDC max rated power See specification table for specific model requirements Appropriate overloading protection should...

Page 7: ...into the SFP receptacle on the front of the module see the SFP Data Sheet 091 17000 001 for supported Gigabit transceivers NOTE The release latch of the SFP fiber transceiver must be in the closed up...

Page 8: ...on 1000 OFF No link Amber Blinking at 1Hz Port not linked at 1000Mbps and receiving AN Remote Fault Green ON Port linked at 1000Mbps Green Blinking at 10Hz Port data activity at 1000Mbps Green Blinkin...

Page 9: ...warranty with 24 7 365 free Technical Support Page 18 Page 17 Description RuggedNet GHPoEBT Si 60 100W BT 10 100 1000BASE T with Gigabit Fiber or Copper Uplinks Ruggedized Unmanaged IEEE 802 3bt PoE...

Page 10: ...kV Air 8 kV IEC 61000 4 3 RS 80 MHz to 1 GHz 10V m IEC 61000 4 4 EFT Power 2 kV Signal 1 kV IEC 61000 4 5 Surge Power 2 kV Signal 1 kV IEC 61000 4 6 CS Signal 10 V IEC 61000 4 8 Magnetic Field IEC 610...

Reviews: