background image

RuggedNet

® 

GHPoE/Si and GHPoEBT/Si

Unmanaged 6 Port 

60W Pre-BT PoE and 60/100W IEEE 802.3bt

Gigabit Switches 

User Manual

38 Tesla,  Irvine, CA 92618 USA

Phone: (949) 250-6510; Fax: (949) 250-6514

General and Copyright Notice

This publication is protected by U.S. and international copyright laws. All rights 

reserved. The whole or any part of this publication may not be reproduced, stored 

in a retrieval system, translated, transcribed, or transmitted, in any form, or by 

any means, manual, electric, electronic, electromagnetic, mechanical, chemical, 

optical or otherwise, without prior explicit written permission of Omnitron Systems 

Technology, Inc.
The following trademarks are owned by Omnitron Systems Technology, Inc.: 

FlexPoint

TM

, FlexSwitch

TM

, iConverter

®

, miConverter

TM

, NetOutlook

®

, OmniLight

®

OmniConverter

®

, RuggedNet

®

, Omnitron Systems Technology, Inc.

TM

, OST

TM

 and 

the Omnitron logo. 
All other company or product names may be trademarks of their respective owners.
The information contained in this publication is subject to change without notice. 

Omnitron Systems Technology, Inc. is not responsible for any inadvertent errors.

Warranty

This product is warranted to the original purchaser (Buyer) against defects in 

material and workmanship for a period of two (2) years from the date of shipment. 

A five (5) year warranty may be obtained by the original purchaser by registering 

this product at www.omnitron-systems.com/support within ninety (90) days from the 

date of shipment. During the warranty period, Omnitron will, at its option, repair or 

replace a product which is proven to be defective with the same product or with a 

product with at least the same functionality.
For warranty service, the product must be sent to an Omnitron designated facility, 

at Buyer’s expense. Omnitron will pay the shipping charge to return the product 

to Buyer’s designated US address using Omnitron’s standard shipping method.

Limitation of Warranty

The foregoing warranty shall not apply to product malfunctions resulting from 

improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-

supplied  equipment,  Buyer-supplied  interfacing,  unauthorized  modifications  or 

tampering with equipment (including removal of equipment cover by personnel not 

specifically authorized and certified by Omnitron), or misuse, or operating outside 

the environmental specification of the product (including but not limited to voltage, 

ambient temperature, radiation, unusual dust, etc.), or improper site preparation 

or maintenance.

No other warranty is expressed or implied. Omnitron specifically disclaims the implied 

warranties of merchantability and fitness for any particular purpose.

The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron 

shall not be liable for any direct, indirect, special, incidental, or consequential 

damages, whether based on contract, tort, or any legal theory.

Page 2

Summary of Contents for RuggedNet GHPoE/Si

Page 1: ...aser by registering this product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its option repair or replace a product...

Page 2: ...dNet GHPoE Si and GHPoEBT Si are industrial unmanaged Ethernet switches that feature fiber or copper uplink ports and four 10 100 1000 RJ 45 copper Power over Ethernet user ports The GHPoE Si is a pre...

Page 3: ...d Uplink Redundancy SW4 Reserved SW5 MAC Learning SW6 Forced PoE Power SW7 L2CP SW8 PoE Reset DIP switch Definitions SW1 and SW2 Mode of Operation The modules support Switch Directed Switch and Dual D...

Page 4: ...ary port F2 Directed Switch Mode with Uplink Redundancy Page 8 Dual Device Mode Dual Device Mode is only supported on models with two uplink ports When configured for Dual Device Mode the module is co...

Page 5: ...PD with non standard detection characteristics The DIP switch controls the forced capability for the RJ 45 user ports on the module When this DIP switch is in the LEFT Off position all RJ 45 user port...

Page 6: ...d the GHPoEBT Si 100W models requires 52 to 57VDC inclusive of tolerances 7 31A 56VDC max rated power See specification table for specific model requirements Appropriate overloading protection should...

Page 7: ...into the SFP receptacle on the front of the module see the SFP Data Sheet 091 17000 001 for supported Gigabit transceivers NOTE The release latch of the SFP fiber transceiver must be in the closed up...

Page 8: ...on 1000 OFF No link Amber Blinking at 1Hz Port not linked at 1000Mbps and receiving AN Remote Fault Green ON Port linked at 1000Mbps Green Blinking at 10Hz Port data activity at 1000Mbps Green Blinkin...

Page 9: ...warranty with 24 7 365 free Technical Support Page 18 Page 17 Description RuggedNet GHPoEBT Si 60 100W BT 10 100 1000BASE T with Gigabit Fiber or Copper Uplinks Ruggedized Unmanaged IEEE 802 3bt PoE...

Page 10: ...kV Air 8 kV IEC 61000 4 3 RS 80 MHz to 1 GHz 10V m IEC 61000 4 4 EFT Power 2 kV Signal 1 kV IEC 61000 4 5 Surge Power 2 kV Signal 1 kV IEC 61000 4 6 CS Signal 10 V IEC 61000 4 8 Magnetic Field IEC 610...

Reviews: