Page 59
To change the individual DIP-switch settings, use the pull-down menu associated with the DIP-switch. The
table below defines the DIP-switch settings. See Section 2.2 on the DIP-switch definitions.
Switch
Function
Soft Switch Configuration Options
1
Device Mode
Single switch mode (factory default)
Dual switch mode
2
Switch mode
Normal switch mode (factory default)
Directed switch mode
3,4
Protection mode
(models with 2 fiber ports only)
No redundant fiber (factory default)
Redundant fiber no return to primary
Redundant fiber return to primary
5
MAC Learning
MAC learning enabled (factory default)
MAC learning disabled
6
Pause
Pause disabled (factory default)
Pause enabled
7
SW7
Reserved
8
PoE Reset
No PoE reset on fiber link drop (factory default)
PoE reset on fiber link drop
Click the “Save” button to save the changes to the DIP-switch Configuration screen.