Short press the page can be performed. Long press to enter the page and setup.
Line 1
Description
State information
Current state information: all possible content shows in the following table,
reference to 7.4 for further information
E-today
The energy generated today in kilo watt hours (kWh)
E-total
The energy generated since starting up the inverter (kWh)
Vpv
The present voltage of the solar generator
Ipv
The present current of the solar generator
Vac
The grid voltage
Iac
The present grid current
Frequency
The grid frequency
Model
The model of the inverter
Standard
Choose standard for different country, reference to 7.3 for further information
Version
Long press to check the firmware version
Temperature
Long press to check the temperature of the inverter
Language
Long press to set language
SN/IP
Long press to check S/N and IP address of the inverter
Date and Time
Long press to set date and time
Grid setting
Long press to set V/F value
Protect setting
Long press to change protect settings
Coefficient setting
Only used in factory
Self Test(for Italy)
Long press to start self-test
P(f)and Q(v)
Long press to set P(f)and Q(v) value
Error Record
Long press to check error record