10
Safety and Protection
Protection Functions
Array ground insulation resistance monitoring Output over current protection Residual current monitoring
Array polarity reverse protection Output over/under voltage protection Surge protection
Array over voltage protection Output over/under frequency protection Anti-island protection
Array over current protection Output short circuit protection Over temperature protection
Protection Class
Ⅰ(
According to IEC 62103
)
Overvoltage Category
PV
Ⅱ
/ Mains
Ⅲ(
According to IEC 62109-1
)
Reference Standard
Safety Standard
IEC/EN 62109-1,IEC/EN 62109-2
EMC Standard
EN 61000-6-1,EN61000-6-3,EN 61000-6-2,EN61000-6-4,EN61000-3-2,EN 61000-3-3
Grid Standard
VDE-AR-N 4105,VDE 0126-1-1,C10/11,G83/2,UTE C 15-721-1,CEI 0-21,
EN50438,NB/T32004,IEC62116,IEC61727,IEC61683,IEC60068
Physical Structure
Dimensions (WxHxD) [mm]
210 * 290 * 90
Weight [kg]
5
Environmental Protection
Rating
IP 65
(
According to IEC 60529
)
Cooling Concept
Natural convection
Mounting Information
Wall bracket
General Data
Operating Temperature
Range [
℃
]
-25 to +60
(
derating above 45
℃)
Relative Humidity
0% to 100%,no condensation
Max. Altitude (above sea
level) [m]
2000
Noise Level [dB]
<
40
Isolation Type
Transformerless
Display
2 LED,Backlight,2 * 16 Character LCD
Data Communication
Interfaces
RS485 / WiFi / GPRS optional
Guarantee
5 - 25 years optional
*The AC voltage and frequency range may vary depending on specific country grid