72
10. Troubleshooting
Fault
No.
Fault Info On
Display
Possible Reasons
Solutions
F00
GFCI Device Fault
Inverter GFCI Detector Issue
1.Restart to check
2.Re-Flash software
3.Replace part or inverter
F01
Island Fault
No Grid or Local Grid
Frequency Isn't Stable
Restart to check after local grid is
stable
Close the protection from the inverter
F03
PV Volt Low
DC voltage is below 150V
1.Correct the installation (Add Panels
More)
2.Re-Flash software
3.Replace part or inverter
F04
Consistency Fault
The Data That Be Master And
Slave CPU Detected Is
Inconsistency
1.Restart to check
2.Re-Flash software
3.Replace part or inverter
F05
Bus Volt Low
1.Test Value Wrongly
2.Software Issue
3.Hardware Broken
1.Restart to check
2.Re-Flash software
3.Replace part or inverter
F06
Bus Volt High
1.Test Value Wrongly
2.Software Issue
3.Hardware Broken
1.Restart to check
2.Re-Flash software
3.Replace part or inverter
F09
No Utility
No AC voltage
Measure AC voltage with a multi
meter
Check the wires in AC cable
F10
Ground Current Fault
1.Poor grounding
2.It Often occurs in the rainy
day.
.Make inverter grounded well
2.Change it to another standard with
wider
protection range under authorization
F11
Bus Unbalance
1.Inverter Control Circuit
Problem
2.Values Of Two Rows Bus
Capacitance Differ Too Much
1.Restart to check
2.Re-Flash software
3.Replace part or inverter
F12
10min Over Volt
Mean Value Within 10min Is
Above 10% Of The Rated Grid
Voltage
Change it to another standard with
wider
protection range under authorization
F13
Over Temp Fault
The temperature of internal
device exceeds 80
℃
It happens rarely and can be used
Normally
Summary of Contents for Omniksol-10k-TL3
Page 2: ......
Page 10: ...8 3 Product Information 3 1 Overview Industrial Layout Excellent Heat Elimination...
Page 48: ...46 Fig Fill in the power station information...
Page 54: ...52 Fig Alert Interface Fig System Setting Interface...
Page 60: ...58 Click Start to continue Click Refresh to search available wireless networks...
Page 64: ...62...