Omnik New Energy Co., Ltd. Omniksol-10k-TL3 User Manual Download Page 48

 

 

46

 

 

Fig. Fill in the power station information 

 

Summary of Contents for Omniksol-10k-TL3

Page 1: ...User Manual V1 5 1 User Manual Installation Operation Omniksol 10k TL3 Omniksol 13k TL3 Omnik New Energy Co Ltd...

Page 2: ......

Page 3: ...3 3 Datasheet 10 4 Packing checklist 12 4 1 Assembly parts 12 4 2 Product Appearance 13 4 3 Product Identification 14 4 4 Further Information 14 5 Installation 15 5 1 Safety 15 5 2 Mounting Instructio...

Page 4: ...communication card 41 8 3 Register on monitoring website 44 8 4 Login monitoring System 48 8 5 WiFi card 53 8 6 Netwoek Settings 54 8 7 Ethernet Card 63 8 8 Installation of Ethernet card 64 8 9 RS485...

Page 5: ...p this user manual all time available in case of emergency 1 2 Symbols Used NOTICE NOTICE indicates a situation that can result in property damage if not avoided CAUTION CAUTION indicates a hazardous...

Page 6: ...are only for qualified personnel who are intended to install or uninstall the Omnik Grid Tie Solar Inverter NOTICE Hereby qualified personnel means he she has the valid license from the local authorit...

Page 7: ...ions including modification of product functionality of any form will affect the validation of warranty service Omnik may deny the obligation of warranty service accordingly DANGER DANGER due to elect...

Page 8: ...shortly after operation Risk of damage due to improper modi cations Never modify or manipulate the inverter or other components of the system NOTICE Public utility only The PV inverter designed to fe...

Page 9: ...NOT touch aluminum housing during operating An error has occurred Please go to Part 10 Trouble Shooting to remedy the error This device SHALL NOT be disposed of in residential waste Please go to Part...

Page 10: ...8 3 Product Information 3 1 Overview Industrial Layout Excellent Heat Elimination...

Page 11: ...onnected Wide MPP voltage range ensure high yield under various weather conditions High MPP tracking accuracy ensure the minimum power loses during converting Complete set of protection methods Also f...

Page 12: ...rrent A 17 0 22 0 Maximum output fault current A 19 0 25 0 Maximum output protection current A 21 0 28 0 Grid Voltage Range V 185 276 185 276 Grid Frequency Range Hz 45 55 55 65 45 55 55 65 Power Fact...

Page 13: ...0529 Cooling Concept Natural convection Mounting Information Wall bracket General Data Operating Temperature Range 25 60 derating above 45 Relative Humidity 0 100 no condensation Max Altitude above se...

Page 14: ...the inside completeness for any visible external damage on the inverter or any accessories Contact your dealer if anything is damaged or missing A B C D E F G H Object Description Quantity A Omnik in...

Page 15: ...cs B Monitoring LCD with backlighting C Function keys for displays and choice of language 4 pcs Bottom Object Description A DC switch B Plug connectors for DC input C Terminal for grid connection AC o...

Page 16: ...n the side name plate The name plate is on the middle part of the right side of the inverter housing And the following figure is the side name plate example as onOmniksol 13k TL3 4 4 Further Informati...

Page 17: ...recommended The installation site MUST have good ventilation condition DANGER DANGER to life due to potential fire or electricity shock DO NOT installs the inverter near any inflammable or explosive...

Page 18: ...t eye level Make sure the wall you selected is strong enough to handle the screws and bear the weight of the inverter Ensure the device is properly fixed to the wall It is not recommended that the inv...

Page 19: ...g minimum clearances to walls other devices or objects to guarantee sufficient heat dissipation and enough space for pulling the electronic solar switch handle Direction Minimum clearance Above 30 cm...

Page 20: ...18 5 4 Mounting Procedure 1 Mark 4 positions of the drill holes on the wall according to the wall mounting bracket in the carton box...

Page 21: ...ugh the mounting holes in the bracket and then tighten the screws into the expansion tubes So far the wall mounting bracket is fixed already 3 Check the 4 holes in the backside of the inverter Then li...

Page 22: ...rner of the inverter as the picture showed below Recommended padlock dimension A Shackle Diameter 5 7 mm B Vertical Clearance 8 15 mm C Horizontal Clearance 12 20 mm Stainless solid hanger and secured...

Page 23: ...R DANGER to life due to potential fire or electricity shock NEVER connect or disconnect the connectors under load NOTICE Electrical connections shall be carried out in accordance with the applicable r...

Page 24: ...y of N L 1 2 conductor 35mm 1 38 PE conductor 40mm 1 57 sheath of AC cable terminal length x about 14mm 0 55 of the inner wrapper then dress the conductor terminals with ferrules or tin soldering 2 Ch...

Page 25: ...ver to tighten it with tightening torque 1Nm 4 Insert the connector to clamp ring with two click sound and then tighten the hex nut with tightening torque 4Nm 5 Finally connect the straight plug to th...

Page 26: ...or each cable section should not exceed the limit below Model Length of cable 2 5 mm2 4 mm2 Omniksol 10k TL3 100m 160m Omniksol 13k TL3 90m 144m NOTICE While installing Omniksol 13k TL3 Separate the P...

Page 27: ...permitted It is unadvisable to use non tinned cables of type H07RN F since with oxidized copper wires the contact resistances of the crimp connection may exceed the permitted limits Disconnected conn...

Page 28: ...l locator and built in crimping insert Crimping range 2 5 4 6 mm 12 10 AWG Type PV CZM 19100 Order No 32 6020 19100 ill 3 Open end spanner PV MS 1 Set 2 pieces Order No 32 6024 ill 4 PV WZ AD GWD sock...

Page 29: ...he cable end L with 6 mm to 7 5 mm of insulation ill 11 Open the clamp K and hold Place the contact in the appropriate cross section range Turn the crimp lugs upwards Release the clamp K The contact i...

Page 30: ...riate end of the test pin into the male or female coupler as far as it will go If the contact is correctly located the white mark on the test pin must still be visible ill 17 Screw up the cable gland...

Page 31: ...sy for user to check and set the data In addition the user can press the function key to illuminate the LCD screen NOTICE Omnik inverter is not an aligned measuring instrument for current voltage or p...

Page 32: ...the inverter installed English Dutch and Deutsch are available for display 7 3 Operation 7 3 1 System operation interface Switch system interface by clicking ENTER System operation interface 1 In this...

Page 33: ...ower and EToday in this interface will change along with the change of number after system operation System operation interface 2 ETotal in this interface will change along with the change of number a...

Page 34: ...to the grid and the grid power factor System operation interface 6 This interface displays the date and time System operation interface 7 This interface displays the temperature 7 3 2 Interface introd...

Page 35: ...33 While Info flickers Confirm to enter Info mode There will be 3 interfaces in the Info mode 1 Software Version 2 SN and model 3 The manufacturer information...

Page 36: ...mode You can choose Set by UP and DOWN key in system operation interface 1 While Set flickers confirm to enter the Set mode The Set mode is operated with 2 levels of menu There are 11 items in the sub...

Page 37: ...choose Language by Up and Down key as shown in the picture While Language flickers confirm to enter the language option list Choose the target language the corresponding language flickers English Dut...

Page 38: ...1 After entering the password system will get to the safety selection interface The selected safety information flickers The selectable safety information as following Italy VDE 4105 VDE 0126 Spain GR...

Page 39: ...own key as shown in the picture Confirm to enter the MPPT setting interface After finishing the setting click ENTER to save the data and return the previous menu 7 Frequency Limit In the Set mode choo...

Page 40: ...g the setting click ENTER to save the data and return the previous menu 9 DC Coef Factory sets the project and users do not need to set it 10 AC Coef Factory sets the project and users do not need to...

Page 41: ...y Falut F05 Bus Volt Low F06 Bus Volt High F09 No Utility F10 Ground Current Fault F11 Bus Unbalance F12 10min Over Volt F13 Over Temp Fault F15 PV Volt High F17 Grid Volt Fault F18 Isolation Fault F1...

Page 42: ...e check the parts according to the below list Contact the manufacturer immediately when you find any damage missing or wrong model Fig GPRS card Omnik provide 2 kinds of GPRS cards One is a standard G...

Page 43: ...w Fig Serial Number 8 2 Installation of communication card Warning Before installing the GPRS card to inverter you must turn off both the AC side and DC side of inverter to make sure personal safety N...

Page 44: ...nterface panel with the screwdriver as shown in Picture above and keep the screws aside Fig Communication box and connector The standard connector has two holes Use the single hole rubber washer to ta...

Page 45: ...N m Fig Insert the GPRS antenna Connect the data line into the I PEX interface Fig Connect the GPRS antenna While using the second kind of GPRS card just insert the SIM card into the card slot Then i...

Page 46: ...nitoring system of Omnik is supported by IE8 Firefox Chrome and Safari Login the website http www omnikportal com click register to enter the user registration page follows the requirements for regist...

Page 47: ...oose the account type Remarks please read the Omnik service agreement carefully the enclosure is the cost list for all the countries please choose your operators End User means the final user you must...

Page 48: ...46 Fig Fill in the power station information...

Page 49: ...47 Fig Fill in the power station information After the register you may enter next chapter 8 4 Login Monitoring System...

Page 50: ...ccount activation open the login interface as below Input the correct email and code Enter the PV monitoring system Then you can monitor and manage the power station Fig Input the email and code Fig U...

Page 51: ...49 Fig List of power station Fig Navigation Bar Not yet open Back to user interface Enter the sharing case Enter the configure company account interface Add one case under your account Reset passwor d...

Page 52: ...50 Fig Main interface of Power Station Change case Case info search Power station info Energy saving Real time power and generated energy switchover Print current figure...

Page 53: ...51 Fig Real Time Interface Fig History Interface Internal temperature Latest data collecting time Parameter options Choose the aim inverter...

Page 54: ...52 Fig Alert Interface Fig System Setting Interface...

Page 55: ...not installed the WiFi card please go to 8 2 Installation of communication card first then go to 8 6 Network Settings After unpacking the box please check the parts according to the below list Contact...

Page 56: ...device e g tablet PC and smart phone that enables WiFi 2 Obtain an IP address automatically Open Wireless Network Connection Properties double click Internet Protocol Version 4 TCP IPv4 Select Obtain...

Page 57: ...twork connection and click View Wireless Networks Select wireless network of the data logging module no passwords required as default The network name consists of AP and the serial number of the produ...

Page 58: ...er and enter 10 10 100 254 the Default IP address of WiFi card you may set domain name access please see the picture 6 14 then fill in username admin and password admin both of which are admin as defa...

Page 59: ...57 b In the configuration interface of WiFi module you can view general information of the module Follow the setup wizard to start quick setting Click Wizard to start admin admin...

Page 60: ...58 Click Start to continue Click Refresh to search available wireless networks...

Page 61: ...Next Notice If the signal strength RSSI of the selected network is 10 which means unstable connection please adjust the antenna of the router or use a repeater to enhance the signal We recommend rout...

Page 62: ...password for the selected network then click Next Select Enable to obtain an IP address automatically then click Next Notice Turn off the firewall of the router Make sure the DHCP function of the rout...

Page 63: ...lick OK to restart If setting is complete the above page will display After your WiFi card set ok and get IP address from your router for example 192 168 16 8 You may see the IP address from inverter...

Page 64: ...62...

Page 65: ...thernet Card Ethernet card is an optional device If your inverter had installed the Ethernet card please go to 8 3 Register on monitoring website If your inverter had not installed the WiFi card pleas...

Page 66: ...fore installing the Ethernet card to inverter you must turn off both the AC side and DC side of inverter to make sure personal safety Unscrew the four screws on the interface panel with the screwdrive...

Page 67: ...Wear the Ethernet cable into the waterproof terminals and waterproof terminals and the cover plate is installed Insert the Ethernet card into the inverter Connect the Ethernet cable to the Ethernet ca...

Page 68: ...the Ethernet cable to the router LAN port 8 9 RS485 card RS485 card is used for external communication device There are 3 connectors in the RS485 card The definition of the connectors is shown in the...

Page 69: ...85 Signal 3 GND RS485 GND CON2 1 A2 RS485 Signal DTSU 666 2 B2 RS485 Signal 3 GND RS485 GND CON3 1 OP Relay Operation Alarm 2 NO Relay Normal Open CON 1 CON 1 is used to communicate with Wi Fi Kit and...

Page 70: ...an be applied for solar projects of self consumption without power export to the grid It can ensure that the power generated by solar system will not export to grid at anytime There are 2 types of met...

Page 71: ...inition of the connector is shown in the table No ammeter 1 Live A grid side 3 Live A inverter side 4 Live B grid side 6 Live B inverter side 7 Live C grid side 9 Live C inverter side 10 N 24 RS485 A...

Page 72: ...as shown below The definition of the connector is shown in the table No ammeter 2 Live A 5 Live B 8 Live C 10 N 1 CT Live A White 3 CT Live A Black 4 CT Live B White 6 CT Live B Black 7 CT Live C Whi...

Page 73: ...n Directive 2012 19 EU on waste Electrical and Electronic Equipment and its implementation as national law electrical equipment that has reached the end of its life must be collected separately and re...

Page 74: ...heck 2 Re Flash software 3 Replace part or inverter F06 Bus Volt High 1 Test Value Wrongly 2 Software Issue 3 Hardware Broken 1 Restart to check 2 Re Flash software 3 Replace part or inverter F09 No U...

Page 75: ...ization F21 PV2 Over Current The input current of PV2 is over rated value May be there is something wrong with the hardware 1 Restart the inverter 2 If the problem persists please replace the inverter...

Page 76: ...ac Voltage at the AC side Vmpp Voltage at the Maximum Power Point Impp Amperage at Maximum Power Point AC Alternating Current Form of electricity supplied by Utility Company DC Direct Current Form of...

Page 77: ...ebsite nl omnik solar com Authorized Service Partner Omnik UK Service Center Address Office 7 2 London Bridge Walk London United Kingdom SE1 2SX Tel 44 0 20171531108 E mail Sales omniksolar co uk Webs...

Page 78: ...er information Product Model Product ID Purchase Date Customer Name Historical Warranty Warranty date Troubleshooting Finished date Customer Signature Client retention User Information Product Model P...

Page 79: ...period is 5 years standard 10 years selectable effective after sealing During the warranty period if the product fails the quality of the original device or the production problem the company provide...