background image

ENGLISH

• 3 •

INSTALLATION 

CONTINUED

1.  Apply about three wraps of plumber tape in clockwise direction to 

pipe threads of each fitting.

2.  If mounting bracket (not supplied) is to be used, attach to cap before 

assembling the fittings. 

NOTE:

 Allow 1

1

2

-inches clearance below housing to enable filter 

cartridge changes.

3.  Assemble all fittings. Start adapters into cap by hand. Use a wrench to 

tighten firmly. DO NOT OVER-TIGHTEN.

4.  Measure length (shown as X on diagram) across assembled fittings 

and subtract 1-inch if you are installing on 3/4-inch pipe, or 1

1

2

-inches 

if you are installing on 1-inch pipe. Mark section of pipe to be 
removed.

5.  Turn off the main water supply valve and open a faucet on the lowest 

level of you home to drain the system. Cut the correct length of pipe. 
Use a pipe cutter or hacksaw. File or sand the ends of the pipe to 
make sure they are smooth and square. 

NOTE:

 Have a bucket handy to catch any water that may come out of 

the pipe.

6.  Align filter assembly with ends of pipe, making certain cap opening 

marked “IN” is facing the incoming water supply. It will be necessary 
to spread ends of pipe apart to install filter assembly. Using two 
adjustable wrenches, hold incoming adapter securely with one wrench 
and tighten nut with second wrench. Repeat procedure for  
outgoing adapter. 
 

WARNING

 Risk of electrical shock. If your water pipes are used 

to ground your house’s electrical system, install a No. 8 AWG jumper 
wire (or larger) around the filter (see Figure 6). The jumper wire 
must be connected at both ends by a pressure wire fitting or other 
connection that satisfies NEC or CEC and local codes.

7.  Slowly turn on water supply to the filter and depress the red pressure-

relief button on cap to release trapped air. Check for leaks. Open the 
nearest faucet and flush for 10 minutes, wait one hour, then flush 
again for 10 minutes.

WHEN TO CHANGE THE CARTRIDGE

The life of the cartridge depends on the water volume used and the 
substances in the water. Normally the cartridge should be changed at 
intervals of three to six months or less. Replace the cartridge sooner if the 
water pressure at the faucet begins to drop noticeably or if you notice 
changes in the taste, color, or flow of the filtered water.

NOTE:

 Certain types of harmless bacteria will attack cellulose material. 

Cartridges containing cellulose, such as the RS15 and TO6, may seem to 
disintegrate, produce a “sewer” or “rotten egg” odor, or form a black 
precipitate due to bacteria. If this happens, consult OMNIFILTER Customer 
Service for advice or select a different cartridge.

2

X

4

Inlet

Outlet

1

5

X

3

Union

Valve

6

No. 8 Jumper Wire

Summary of Contents for BF9C

Page 1: ...ns Optional Materials BF7MB Mounting Bracket Jumper Wire See your Local Dealer Parts Included Housing RS6 Cartridge OW60 Housing Wrench Herramientas y conexiones necesarias 2 llaves ajustables o llave...

Page 2: ...ter being filtered indicate that the cartridge should be replaced Use only OMNIFILTER replacement cartridges This installation must comply with all applicable state and local regulations Use only plum...

Page 3: ...urely with one wrench and tighten nut with second wrench Repeat procedure for outgoing adapter WARNING Risk of electrical shock If your water pipes are used to ground your house s electrical system in...

Page 4: ...DO NOT OVER TIGHTEN Turn on water supply slowly to allow filter to fill with water Depress red pressure relief button to release trapped air Check for leaks before leaving installation NOTE After inst...

Page 5: ...15 000 gals or 3 months 15 000 gals or 3 months 15 000 gals or 3 months 15 000 gals or 3 months 15 000 gals or 3 months 15 000 gals or 3 months 3 000 gals or 1 month Recommended Flow Rate 10 gpm 10 g...

Page 6: ...ESPA OL 6 Notes Notas Remarques...

Page 7: ...rtucho filtrante de repuesto que se usa con este sistema tiene una duraci n de servicio limitada Los cambios en el sabor olor y caudal del agua filtrada indican que se debe cambiar el cartucho Use s l...

Page 8: ...tar firmemente el adaptador de entrada con una y apretar la tuerca con la otra Repita el procedimiento para el adaptador de salida ADVERTENCIA Peligro de choque el ctrico Si las tuber as de agua de su...

Page 9: ...descargue agua por el cartucho de nuevo durante 10 minutos antes de usar el agua NOTA Use nicamente cartuchos de repuesto OMNIFILTER leg timos para obtener los mejores resultados El incumplimiento de...

Page 10: ...cidad del filtro 113 562 litros o 6 meses 56 782 litros o 3 meses 56 782 litros o 3 meses 56 782 litros o 3 meses 56 782 litros o 3 meses 56 782 litros o 3 meses 56 782 litros o 3 meses 11 356 litros...

Page 11: ...l eau filtr e indique que la cartouche filtrante doit tre remplac e Utilisez exclusivement des cartouches de rechange OMNIFILTER L installation doit tre conforme tous les r glements provinciaux et loc...

Page 12: ...molette tout en serrant l crou avec l autre R p tez cette proc dure sur le raccord de sortie PRECAUCI N Risque de choc lectrique Si les conduites d eau servent la mise la terre du circuit lectrique du...

Page 13: ...r sur le couvercle et serrez le la main NE SERREZ PAS TROP FORT Ouvrez l eau lentement pour laisser le filtre se remplir d eau Appuyez sur le bouton rouge de d pressurisation pour vacuer l air Avant d...

Page 14: ...or 3 mois 15 000 gals or 3 mois 15 000 gals or 3 mois 15 000 gals or 3 mois 15 000 gals or 3 mois 3 000 gals or 1 mois D bit recommand 38 Lpm 38 Lpm 38 Lpm 38 Lpm 38 Lpm 38 Lpm 38 Lpm 38 Lpm Usage av...

Page 15: ...15 Notes Notas Remarques...

Page 16: ...e serie si lo tiene junto con una explicaci n breve del problema DENTRO DEL L MITE M XIMO PERMITIDO POR LA LEY APLICABLE OMNIFILTER RECHAZA TODA OTRA GARANT A YA SEA EXPRESA O IMPL CITA INCLUSO PERO S...