Figure 17
CYCLE DEFAULTS TABLE
OM34K Recharge Cycles:
Table 1
Length of Cycle
Time remaining to
end of cycle
Cycle
Cycle
Description
HE
Setting
HC
Setting
HE
Setting
HC
Setting
1
Backwash 1
10 min
10 min
76 .5 min
117 .5
min
2
Brine Draw
54 min
82 min
66 .5 min
107 .5
min
Slow Rinse
3
Re-
Pressurize
3 min
3 min
12 .5 min
25 .5 min
4
Fast Rinse 1
4 min
4 min
9 .5 min
22 .5 min
5
Backwash 2
1 min
1 min
5 .5 min
18 .5 min
6
Fast Rinse 2
1 min
1 min
4 .5 min
17 .5 min
7
Refill
3 .5 min
16 .5 min
3 .5 min
16 .5 min
*The camshaft does not move between Brine Draw and Slow Rinse.
Slow Rinse begins when the brine in the salt tank runs out and the
check valve closes.
OM40K Recharge Cycles:
Table 1
Length of Cycle
Time remaining to
end of cycle
Cycle
Cycle
Description
HE
Setting
HC
Setting
HE
Setting
HC
Setting
1
Backwash 1
10 min
10 min
74 .1 min 118 .1 min
2
Brine Draw
51 min
79 min
64 .1 min 108 .1 min
Slow Rinse
3
Re-
Pressurize
3 min
3 min
13 .1 min
29 .1 min
4
Fast Rinse 1
4 min
4 min
10 .1 min
26 .1 min
5
Backwash 2
1 min
1 min
6 .1 min
22 .1 min
6
Fast Rinse 2
1 min
1 min
5 .1 min
21 .1 min
7
Refill
4 .1min
20 .1 min
4 .1 min
20 .1 min
*The camshaft does not move between Brine Draw and Slow Rinse.
Slow Rinse begins when the brine in the salt tank runs out and the
check valve closes.
OM34K Recharge Cycle Requirements:
Minimum Salt/
Capacity
Maximum Salt/
Capacity
Salt/Recharge (lbs)
3 .4
16 .7
Regeneration Time
(min)
76 .5
117 .5
Water to Drain (gal)
46 .3
56 .9
Max . Flow to Drain
(gpm)
2 .1
2 .1
OM40K Recharge Cycle Requirements:
Minimum Salt/
Capacity
Maximum Salt/
Capacity
Salt/Recharge (lbs)
4 .1
20
Regeneration Time
(min)
74 .1
118 .1
Water to Drain (gal)
58 .7
72 .1
Max . Flow to Drain
(gpm)
2 .7
2 .7
START-UP
The conditioner will now need to be placed into operation .
Please review Quick Cycling the Control procedure before
attempting start-up .
DO NOT put regenerant material into the brine tank .
1 .
With the supply water for the system still turned off, position
the bypass valve to the “not in bypass” (normal operation)
position .
Both valve
handles pointing
in direction of
water flow
2 . Press and hold the button on the controller for 3
seconds. This will initiate a manual regeneration, and cycle
to the backwash position .
3 . Filling the media tank with water .
A .
With the conditioner in backwash, open the water
supply valve very slowly to approximately the 1/4 open
position . Water will begin to enter the media tank . Air
will begin to be purged to drain as the media tank fills
with water .
WARNING:
If opened too rapidly or too far, media may
be lost out of the tank into the valve or the
plumbing. In the 1/4 open position, you
should hear air slowly escaping from the
valve drain line.
B . When all of the air has been purged from the media
tank (water begins to flow steadily from the drain line),
open the main supply valve all of the way. This will
purge the final air from the tank.
C . Allow water to run to drain until the water runs clear
from the drain line . This purges any debris from the
media bed .
D . Pour about 3 gallons of water into the brine tank .
Advance to cycle 2 (Brine Draw) by pressing the
and buttons at the same time . The water in the brine
tank should be drawn into the valve. If the water is not
receding from the tank, refer to Troubleshooting.
E .
Quickly cycle the control to the refill cycle (C7). Place
salt in brine tank. Allow this cycle to finish and the
control to move to service. The brine tank will have the
correct amount of water .
WARNING:
Ensure that the system has been properly
disinfected per the water conditioning
system manufacturer's recommendations.
The water conditioning system is now fully operational.
The display will show the hour of the day . The decimal point at
bottom center of the display will blink when water is flowing.
OM34K and OM40K OC11 • 11