Diagnostic Codes .
NOTE: If a button is not pushed for 30 seconds the
controller will exit the history table.
Press the Time of Day button to increment through the
table. When the desired code is reached, Press the Salt
Amount button
to display the value.
Some of the values have four digits 1, 2, 3, 4. Press the Salt
Amount button
to display the first two (1, 2). Press the
Water Hardness button
to display the last two (3, 4).
When the Salt Amount button
is pressed to view H2 the
current flow rate will be displayed but not updated. Continue to
press and release the Salt Amount button
every 5 seconds
to update the display. The flow dot on the display will flash
when there is flow thru the softener.
Code
Description
Notes
H1
Days since last recharge
Days since last recharge
H2
Current flow rate
Gallons per minute
H3
Current day of week
Current day of week
H4
Water used today since 0200
In gallons,
max value displayed 9999
max value stored 65,535.
H5
Water used since last recharge
A0
Average water usage for day 0
A1
Average water usage for day 1
A2
Average water usage for day 2
A3
Average water usage for day 3
A4
Average water usage for day 4
A5
Average water usage for day 5
A6
Average water usage for day 6
OM34K and OM40K OC11 • 13