![Omnicomm LLS 20230 Installation Manual Download Page 35](http://html1.mh-extra.com/html/omnicomm/lls-20230/lls-20230_installation-manual_4023364035.webp)
Appendix I. Example of Setting Offset Values and Measurement
Range
Initial data:
Fuel tank with the installed Product (Figure 43)
Fuel tank depth: 700 mm
Sensor working length: 680 mm
It is required to set the product in such a way that the fuel level is measured in
millimeters with the scale factor of 0.5 mm.
Solution:
Set measurement range value: 1,360;
Offset value: 40.
Therefore, the level value is reduced to millimeters with the scale factor of 0.5mm.
35
Connection
Summary of Contents for LLS 20230
Page 29: ...Appendix D Connecting the Product to a PC 29 Connection...
Page 32: ...Appendix F BIS 20240 Installation Dimensions 32 Connection...
Page 38: ...38 Connection...
Page 48: ...48 Connection...
Page 49: ...Appendix M Strengthening Flange for LLS 20230 Fuel Level Sensor 49 Connection...
Page 50: ...info omnicomm world com www omnicomm world com...