1-6
OmniTrack Installation and Programming Instructions
Programming the OmniTrack
OmniTrack Installation Guide
/67-2055 Rev A
© 2009 Omnicell, Inc.
Row Two
: Host zone (physical location of the OmniTrack)
Row Three
: Bin type (32 button switch panel or 32 button supply drawer)
Row Four
: Exit buttons
Figure 1-9.
Program the OmniTrack for zone, physical location, and bin type using the following
directions:
Zone Address
Use the top row of LEDs to set the zone address. Binary numbering (starting from the far left
button; 1,2,4,8,16,32,64) is used.
The eighth button is not used.
Figure 1-10.
Several sample addresses are shown below:
If the OmniTrack is being used for off-Omni items or for SecureTrack items, set the zone address
to Zone 9 or any other appropriate auxilliary/imaginary zone.
If the OmniTrack is being used for pharmacy items with a refrigerator either on or off the
OmniSupplier, set the zone address to the zone in which the OmniTrack is physically located.
Row 1
Row 2
Row 3
Row 4
Button#
1
2
3
4
5
6
7
Binary Value
1
2
4
8
16
32
64
off
off
off
off
off
off
off
= Zone 0
ON
off
off
off
off
off
off
= Zone 1
off
ON
ON
off
off
off
off
= Zone 6 (2+4)
ON
ON
ON
ON
off
off
off
= Zone 15 (1+2+4+8)