14 Reference & Installation Manual
4.3 CHECK-IN SUPERVISION TIMER SETTINGS
SECTION
[001] :
OPTIONS
[3]
AND
[4]
Options [3] and [4] define the time period that must elapse before the Omnia
transmitters send a status signal to the Wireless Receiver Module. For example, if
the timer is set to 12 minutes (option [3]=on ; option [4]=off), the transmitters will
send a status signal every 12 minutes to the Receiver Module. For high-security
installations select the lowest check-in time (6 minutes). Selecting the longest
check-in time (12 hours) will conserve battery power.
Ensure that the assigned detectors and door contacts are set to the same
Check-In time period as the Receiver Module. For example, if the Receiver
Module is set to 12 minutes, the detectors and door contacts must also be
set to 12 minutes.
How to enable check-in supervision.
In step 5 in Figure 3.3 on page 7:
1. Enter section [001].
2. Enable or disable option [2].
Option [2] OFF = Check-In Supervision disabled (default)
Option [2] ON = Check-In Supervision enabled
How to set the check-in supervision timer.
In step 5 in Figure 3.3 on page 7:
1. Enter section [001].
2. Enable or disable options [3] & [4].
Option [3] OFF = hours (default)
Option [3] ON = minutes
Option [4] OFF = 12 (default)
Option [4] ON = 6