12 Reference & Installation Manual
3.8 SYSTEM RESET
Performing a system reset will erase all the sections in the Wireless Receiver
Module's programming and set the following section to default settings:
How to view unknown serial numbers.
From Step 5 in Figure 3.3 on page 7:
1. Enter section [030].
2. Press and hold the tamper switch on the detector or door contact.
On an LCD keypad, the device's serial number appears on the LCD screen
under the words “View Data”.
On an LED keypad, the first number of the device's serial number will
illuminate (10 = zero). Press the [
!
!
!
!
] button to view each subsequent
number. When you press the [
"
"
"
"
] button on the last number of the serial
number, the control panel will exit the section.
Section #
Default Settings
[001]
Options 1 to 8 = OFF
How to reset the system.
1. Press and hold the [0] button.
2. Enter the [
INSTALLER CODE
] (default=000000).
3. Enter the appropriate [section number]:
Digiplex = [951]
DigiplexNE = [4001]
4. Enter the Omnia Wireless Receiver [