The T110/R130 system has 3 available startup and shutdown modes that can be configured with the following steps.
Changing Start Up and Shutdown Configuration
A. The cap is held on by two plastic tabs at
opposing sides, which can be unlatched
as shown using a screwdriver. Once the
cap is free, the R130 can slide open.
B. Supply power to the receiver. The (E-Stop)
light and the (Link) light will come on RED
and the (Status) light will come on GREEN
1. Opening the R130 Case and Power the R130
2. Power T110 into Configuration Mode & Enter Configuration Password
A. Power T110 into configuration
mode by following Step #3 from
Download ID Code
B. Press function buttons in order 3,
1, 4, 2
C. Press Power [ON] button
C.
B.
A.
ESTOP FAULT LINK STATUS
A. B.
3. Enter Start Up and Shut Down Code
Enter the 10-digit Configuration Code associated with one of the following startup and shutdown modes:
ON / OFF Mode
1188888888
ON
normal.
OFF
when T110 / R130 link is lost.
Secure Mode
4188888888
ON
by entering the “3, 1, 4, 2” password on the T110 and pressing the
GREEN [Power] button.
OFF
when T110 / R130 link is lost.
Auto Power Down Mode
5188888888
ON
normal.
OFF
when T110 / R130 link is lost or after 10 minutes of
being
idle.
NOTE:
If left idle in Setup Mode for over 30 seconds, the receiver will time out. The (Link) light and (Status) light will flash RED rapidly. To return to
Setup Mode, repeat step 4.
A. Press & hold [Setup] button
until (Status) light goes from
slow flash to fast flash
B. Release [Setup] button.
(Status) light goes to solid
GREEN, (Link) light turns off
B.
4. Put R130 into Setup Mode
A.
Setup
Button
ESTOP FAULT LINK STATUS
Setup
Button
ESTOP FAULT LINK STATUS
5. Send Code
A. Press Power [ON] button
B. (Link) light goes to GREEN.
C. Once complete, (Link) light turns off and the
(Status) light begins to slow flash, as the
transmitter turns off
D. Cycle the power off and on again on the
R130 receiver and power up the T110 trans-
mitter. The two units will now be linked.
A.
Light Legend
Solid
Slow Flash
Fast Flash
Red Light
Green Light
Yellow Light
ESTOP FAULT LINK STATUS
3
1
4
2