Setup Procedure
10
4.
Controls and Indicators
OmiDetect’s display has a series of 6 LEDs and a Low Battery Indicator
LED.
Figure 2. OmiDetect's LED Display.
The 6 LEDs have three functions:
The first LED (1) illuminates when the “Listen” mode is
selected, letting you test a TPM sensor activated manually,
rather than electronically using OmiDetect.
The middle four LEDs (2) indicate the TPM sensor type
currently selected for testing. For example, when the 2nd and
3rd LEDs are illuminated, the TRW sensor type is selected.
Refer to Sec. 8, TPM Sensor Type Selection Chart, for the
combination of LEDs to be illuminated for the sensor type you
wish to test.
The middle two LEDs (2) indicate the frequency of the response
RF signal detected from the TPM sensor under test, either
315MHz or 433MHz.
The next LED (3) illuminates to indicate a valid sensor signal
was not detected during the test cycle.
Note : On power On OmiDetect automatically reverts to the last
test mode used.