![Omicron CPC 100 User Manual Download Page 10](http://html2.mh-extra.com/html/omicron/cpc-100/cpc-100_user-manual_3990074010.webp)
CPC 100
V 3.20
Introduction - 5
Note:
Unlike the other menu items, the two
Save…
functions of the main
File Operations
menu
directly effect the currently open test, i.e., the test procedure that was composed in the Test
Card View, or the test that was loaded in the
CPC 100
file system beforehand.
Therefore, pressing
Save
, for example, does not save the test that you may have highlighted in
the folder tree, but the one that is currently open.
Submenu File
Submenu Edit
Note:
If a folder is cut or copied to the Clipboard, the selection is recursive, i.e., all of its
subfolders will also be put to the Clipboard.
Cutting or copying a test or folder, and trying to paste it in the same location, opens the
String
Editor
.
Since a test or folder cannot exist twice under the same name at the same location, determine
a new name for it using the
String Editor
.
Device Setup
Opens the
String Editor
. You can create a new folder with any name of your choice.
Appends the contents of a test file (
.xml
) or template (
.xmt
) of your choice to the
currently open test.
Deletes the currently selected test or folder from the
CPC 100
’s disk space.
Opens the
String Editor
that enables you to rename the current test to any new
name of your choice.
(for future use)
Closes the submenu and returns to the main
File Operations
menu.
Set the external booster you
want to use (CB2, CU20 or
CU1).
Set current clamp
parameters and CT and/or
VT transformation ratio.
Select the check box if the
PE connection is intact and
an error message (313)
appears.
Operating the CPC 100
with the check box
selected can cause injury
or possibly death of the
operating staff!
Set the default frequency.
This value will be used for all
test cards.
Auto save
automatically
saves the current test
settings in fixed intervals
specified to a file named
lastmeas.xml
.
Resets all user-specific settings made in the
CPC 100
software to factory-defined defaults
including:
•
the test card defaults
•
the test procedure default
•
all settings made at the
Device Setup
tab
(Sets external booster to CB2, sets CT and
VT to “OFF” and sets the default frequency
to 50 Hz.)
•
the String Editor’s template strings
If selected, the CPC 100 cools down faster.
Thus, the duty cycle can be increased.
The
CPC 100
File System
The Options Menu
Select the test of your choice. Press
Cut
to put the selected test or folder to the
Clipboard. Proceed with
Paste…
Select the test of your choice. Press
Copy
to copy test or folder to the
CPC 100
clipboard. Proceed with
Paste…
Move to the destination folder of your choice. Press
Paste
to insert the contents of
the
CPC 100
clipboard to this folder.
Press
Paste As Templ.
to make the contents of the
CPC 100
clipboard a test
procedure template.
(for future use)
Closes the
Edit
submenu and returns to the main File Operations menu.