Test Set CMC 156
32
5.2 Outputs
The data given in the following table are valid for all generator outputs,
regardless of the amplifiers used (internal or external ones); the following
tables are valid only for equipment with internal amplifiers.
For the block diagram of the generator outputs available please refer to
Figure 3 on page 18.
Analog current and voltage outputs
Frequency range
1
Sinusoidal
signals
Transient
signals
10 to 1000 Hz
DC to 3.1 kHz
Frequency resolution
5 µHz
Frequency accuracy
0.5 ppm
Frequency drift
1 ppm
Phase range
- 360 ° to + 360 °
Phase resolution
0.001 °
Phase error
2
typ. 0.02 °
Guaranteed < 0.1 °
Table 11
Analog current and voltage outputs
1
If you purchased the option
FL-6
, the maximum output frequency is constrained to
599 Hz
.
2
Valid for sinusoidal signals with 50 / 60 Hz.