101-050
INSTRUCTIONS
pag.25
O.M.F.B. S.p.A. Hydraulic Components
We reserve the right to make any changes without notice.
Edition 2017.09 No reproduction, however partial, is permitted.
Via Cave, 7/9 25050 Provaglio d’Iseo (Brescia) Italy Tel.: +39.030.9830611
Fax: +39.030.9839207-208 Internet:www.omfb.it e-mail:[email protected]
W
ire
L
ess
Codice fascicolo: 997-101-50380
3. G
ENERAL
DESCRIPTION
OF
CONTROLS
AND
INDICATIONS
Start-up
Power on
• Switching on
• Switching off
• Re-enabling after emergency
• Changing channel
Emergency
Ascent
Descent
3.1
G
ENERAL
OPERATION
Turning on the TX the system checks receiver presence and once identified and communicating the yel-
low “Link” led comes on. If the yellow “Link” key led does not come on when the transmitter is turned
on, check that the transmitter is powered (in particular, check that the battery disconnector on the tip-
up container with mini powerpack is inserted and on).
If the yellow “Link” led should go off and
flash during operation, this means it is not within the max working distance allowed between
the transmitter and the receiver, which is 5 metres. (For needs/applications requiring greater
distances check other OMFB catalogue products).
On pressing the Up key (in the picture) the fol-
lowing occurs: in “man present” mode (that is, output on for as long as the key is pressed) of the corre-
sponding Up outlet which in wiring corresponds to the violet wire tension level being taken to the power
voltage level. On pressing the Down key (in the picture) the following occurs: in “man present” mode
(that is output on for as long as the key is pressed) of the corresponding down outlet which in wiring cor-
responds to the solenoid valve connector Blue wire tension level being taken to the power voltage level.
N.B. To better understand operation, refer also to
the COMPLETE FUNCTIONAL DIAGRAM on page 34
of this manual.
Codice foglio:997-101-50376 R
ev: AA
Data: V
enerdì 08 novembre 2019