ASSEMBLY

 With a flashlight, look into the mounting hole that will receive the anemometer axle shaft, on the

back of the wind cups. Check that the set screw is backed off appropriately, not obstructing the

opening.

 Place the wind cups over the axle shaft protruding from the anemometer housing and gently slide

into place.

 Insert the Allen wrench tool provided into the wind cups opening and tighten the small set screw

inside.

 Test to assure the wind cups are securely mounted on the anemometer shaft and spin freely

BATTERY INSTALLATION

 Remove four (4) screws from the battery compartment with a small Phillips screwdriver.

 Open the battery compartment and install 2 “AA” batteries (not included) matching the polarities

shown.

 Replace the battery compartment door and secure the screws.

ALIGNING

 Point the wind direction vane to the North (use a compass or map if necessary).

 Press “SET” opening located inside battery compartment with a paper clip or similar tool. This will

“SET” the local wind direction to North. Continued pressing of “SET” alternately toggles wind

direction between the factory default preset or user set direction.

NOTE:

Repeat this procedure every time after whenever changing the batteries.

MOUNTING

Securely mount the anemometer base to an appropriate vertical surface, using the fittings provided.

PLACEMENT TIPS:

 The anemometer should be mounted in an open area with unobstructed air flow; away from the

nearby trees, buildings or other structures.

 Aim for a maximum exposure of the anemometer to the most common wind directions in the area.

 The suggested mounting height for the anemometer is 33 feet (10meters) above the ground.

MAIN UNIT

The main unit should be placed indoors. It measures: pressure, indoor temperature, humidity, and
receives the US Atomic Clock data and data from each of the remote weather sensors.

FEATURES

Time

 Precise time and date set via RF signals from US Atomic clock

 Selectable 12 or 24 hour time format

 Manual adjustment of time and date

 Calendar displaying date with month and day in 6 languages: English, German, French, Italian,

Spanish and Dutch

 Sunrise/set calculation for over 100 pre-programmed world cities in accordance with the

geographical information entered by the user

 Moon Phase calendar and historical data for the past and future 39 days

 Dual crescendo alarms with programmable snooze

Weather

 Weather forecast for the next 12 to 24 hour in seven large icons: Sunny, Partly Cloudy, Cloudy,

Light Rain, Heavy Rain, Snowy and Unstable.

 Barometric pressure in imperial or metric units

 Altitude adjustment for pressure compensation

 24 hour barometric pressure history chart

 Multiple weather alarms

 Indoor/Outdoor Temperature & Humidity in up to 3 remote locations (additional sensors required)

 Dew point and comfort level indicators

 Wind speed and wind gust averages and memory

 Wind direction

 Rainfall amount with minimum and maximum memory

 Operating range from 100 feet (30 meters) up to 328 feet (100 meters)

Display

 Light sensor detects low light conditions and LCD lights up automatically when adapter is

connected

Power

 7.5 V AC/DC adapter for automatic remote control

 4 “AA” batteries

BATTERY INSTALLATION

 Open the battery compartment door on the back of the main unit.

 Insert 4 “AA” batteries according to the polarities shown and replace the battery compartment

door.

 Connect 7.5 V AC/DC adapter provided to the main display unit and plug into to the wall power

outlet.

NOTE: 

The AC/DC adaptor connection is required for automatic backlight control function. When the

main unit operates on battery power alone, the auto backlight control function is disabled.

 Connect the table stand to the back of main unit when placing on a table or other horizontal

surface.

 When mounting the main unit on the wall or vertical surface, detach the table stand and use the

mounting hardware provided.

Placement tips

 Make sure that the main unit is locating within the operating range of all remote weather sensors.

 Ideally the remote weather sensors should be mounted within the line-of-sight of the main unit.

 Transmission range may be affected by trees, metal structures and electronic appliances.

 Test reception before permanently mounting all the remote weather sensors.

Avoid placing the main unit in the following areas:

 Direct sunlight and surfaces emitting and radiating heat, such as heating ducts or air conditioners.

 Areas with interference from the wireless devices (such as cordless phones, radio headsets, baby

listening devices) and electronic appliances.

OPERATION

Once the main unit is powered, the display will show all available LCD segments for a moment.

IMPORTANT:

All of the display functions will be locked, allowing setting your local altitude or sea level

pressure parameters.

The locked display will show the pressure and weather forecast icon 

and abbreviation “hPa/

mBar” flashing, indoor temperature and humidity readings and default time “12:00pm”.

BUTTONS AND CONTROLS

A. 

UP

- Mode Selection: selects the next available mode counter-clockwise
- When programming: increases parameters

B. 

DOWN

- Mode Selection: selects the next available mode clockwise
- When programming: decreases parameters

C. 

SET

- Rotates display for current mode
- Press and hold: to enter the programming mode
- Locks in: set parameters

D. 

CHANNEL

- Manually selects the channel # for receiving temperature and humidity 

sensor data

- Enables the temperature and humidity channel auto-scan mode

E. 

MEMORY

- Records: moon phase, temperature, humidity, rainfall and wind records. 

Then stores in memory

- Moon phase: determined by the day of month interval
- Sets and stores pressure & altitude units in Memory

F. 

HISTORY

- Allows displaying the sea-level pressure history

G. 

ALARM/CHART

- Displays alarm times and programmed alerts for temperature, 

rainfall and wind

- Press and hold, to enter the alarm/alert programming mode
- Press and hold in pressure and forecast window, to view different bar charts

H. 

LIGHT SENSOR

-

Sets the light sensor to: automatic, on or off

– AUTO, ON, OFF

I. 

SENSITIVITY

- Adjusts the automatic light sensor sensitivity

– HIGH/LOW

J. 

LIGHT/SNOOZE

- Illuminates the display backlight for 5 seconds
- Activates Snooze delay for alarms (programmable 1 to 15 minutes)

K. 

AC/DC ADAPTOR 

- Connects main unit to the power outlet through the AC to 7.5V DC adapter 

INPUT

provided

3

Summary of Contents for WMS831

Page 1: ...e mail info omega com For latest product manuals omegamanual info WMS831 Wireless Data Logging Weather Station Shop online at omega com User sGuide MADE IN CHINA...

Page 2: ...Managed by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free...

Page 3: ...her sensors and the main unit BEFORE permanently mounting them outside BEFORE YOU BEGIN We recommend using alkaline batteries for the remote weather sensors and the main unit when temperatures are abo...

Page 4: ...l counting electronics E BATTERY COMPARTMENT Holds 2 AA size batteries F SCREWS Secure battery compartment cover G BUILT IN LEVELER Allows leveling rain gauge on the surface H BUCKET SEE SAW MECHANISM...

Page 5: ...atically when adapter is connected Power 7 5 V AC DC adapter for automatic remote control 4 AA batteries BATTERY INSTALLATION Open the battery compartment door on the back of the main unit Insert 4 AA...

Page 6: ...e adjusted to high or low using the switch located on the back panel NOTE For an automatic control function the main unit must be plugged into the wall power outlet via the AC DC adaptor provided USIN...

Page 7: ...just the latitude Press and hold down either button for quick digits advance Press SET to confirm the selection Continue setting the longitude using the same steps Set the Time Zone by pressing UP or...

Page 8: ...ode press the MEMORY button to recall a current temperature and humidity minimum temperature and humidity or maximum temperature and humidity at the remote location RESETTING THE REMOTE TEMPERATURE AN...

Page 9: ...Then press and hold DOWN on the main unit or handheld remote to enforce a search for all remote signals If this does not work check the wireless transmission path from the corresponding weather senso...

Page 10: ...ampling Interval 10 seconds Wind Direction Range 0 to 360 Resolution 22 5 Accuracy 11 25 Starting Threshold 3mph 4 8 Km h Transmitting interval 33 seconds Rainfall 1h 24h yesterday range 0 to 78 73 in...

Page 11: ...ity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial...

Page 12: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...