16 |
P a g e
5.2.1.5
Sensor Writeable
If the Sensor Writeable bit is set the sensor value may be overwritten with a preset value. This capability is useful in
sensors such as up/down counters, where a preset, or possibly a zero value must be written to the sensor value.
5.2.1.6
Smart Sensor
Refer to the
Smart Sensor Device Interface
documentation.
5.2.2
DIO Input Configuration
DIO Input Configuration
7
6
5
4
3
2
1
0
Available Assigned
Apply
Scaling
Lock
Sub Channel Selection
0
0
1
?
0x03 == bits 0 and 1
5.2.2.1
Lock
If set, the user specified units of measure string (4-character maximum) will be used in place of the default
DIN.
5.2.2.2
Apply Scaling
If set, the user defined Offset and Gain values will be used to adjust the sensor reading:
Result = (Raw Reading * Gain) + Offset
5.2.2.3
Assigned
The Assigned bit will always read as 0. Refer to the
Smart Sensor Device Interface
documentation for further
information.
5.2.2.4
Available
The Available bit will always read as 0. Refer to the
Smart Sensor Device Interface
documentation for further
information.
5.2.3
DIO Device Configuration
The DIO Device Configuration allows enabling each of the 2 input bits and selecting whether the input is active HIGH
or active LOW. If the Invert Bit is set the signal will be Active Low.
DIO Device Configuration
7
6
5
4
3
2
1
0
Reserved
DIN 1
DIN 0
0
0
0
0
ENABLE
INVERT
ENABLE
INVERT
1
1
1
1
5.2.4
DIO IPSO Definition
The DIO input IPSO definition provides signal range, measured min/max values, IPSO object type information. The SP-
010 DIO IPSO definition is at base address 0x08a8.
Offset
Name
Value
Description
0x00
Sensor Type
3349
Bit Mapped Digital
0x02
Precision
0
Provides reading of xxx
0x04
Reset Min/Max
??
Write any value to force reset of min / max
0x08
Min Measured
??
Minimum reading since last reset
0x0c
Max Measured
??
Maximum reading since last reset
0x10
Min Range
0
Minimum reading
0x14
Max Range
3
Maximum reading