9-5
Specifications
9
Output Scaling - Analog Output Accuracy:
Mode Accuracy Resolution Range
Scalable
MA ±0.1% FS 8 uA
4 to 20.2 mA
-1000 to +100000 Process
Units
V1
±0.2% FS 1 mV
0 to 5.05V
-1000 to +100000 Process
Units
V2
±0.1% FS 1 mV
0 to 10.1V
-1000 to +100000 Process
Units
TC
±2.0°C
1°C/1°F
-75°C (-103°F) to 1370°C (2498°F) Not
Scalable
Dimensions
UWTC-REC1,
UWTC-REC2:
91 L x 62 W x 22 mm H (without antenna)
UWTC-REC1-NEMA, UWTC-REC1-915-NEMA,
UWTC-REC2-D-*-NEMA:
160 L x 90 W x 47 mm H
Weight:
UWTC-REC1,
UWTC-REC2:
935 grams; (2.1 lbs) with antenna
UWTC-REC1-NEMA,
UWTC-REC1-915-NEMA,
UWTC-REC2-D-*-NEMA:
Approx. 635 grams (1.4 lbs)
Enclosure/Housing:
UWTC-REC1,
UWTC-REC2:
Painted Steel
UWTC-REC1-NEMA, UWTC-REC1-915-NEMA,
UWTC-REC2-D-*-NEMA:
NEMA 4x ABS plastic
9.4 UWTC-REC4 Specifications
Power:
12 to 24 Vdc @ 250 mA
Analog Output:
4 independent, non isolated, retransmission
0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA
Output Scaling - Analog Output Accuracy
Mode Accuracy Resolution Range
Scalable
MA ±0.1% FS 8 uA
4 to 20.2 mA
-1000 to +100000 Process
Units
V1
±0.2% FS 1 mV
0 to 5.05V
-1000 to +100000 Process
Units
V2
±0.1% FS 1 mV
0 to 10.1V
-1000 to +100000 Process
Units
TC
±2.0°C
1°C/1°F
-75°C (-103°F) to 1370°C (2498°F) Not
Scalable
Alarms (Programmable):
One per channel, rising/falling activation
Alarm Type:
10K pull-up to Alarm Power (Terminal 6),
200 mA Max
Power, Output, Alarm Connection:
Screw terminals
Operating Ambient:
0 to 55°C (32 to 131°F),
90% RH non-condensing
Radio Frequency (RF)
Transceiver Carrier:
ISM 2.4 GHz, direct sequence spread
spectrum