background image

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our 

customers the latest in technology and engineering.
OMEGA is a trademark of OMEGA ENGINEERING, INC.
© Copyright 2018 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, 

reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior 

written consent of OMEGA ENGINEERING, INC.

FOR 

WARRANTY

 RETURNS, please have the  

following information available BEFORE contacting 

OMEGA:
1.   Purchase Order number under which the product 

was PURCHASED,

2.   Model and serial number of the product under 

warranty, and

3.  Repair instructions and/or specific problems  

  relative to the product.

FOR 

NON-WARRANTY

 REPAIRS, consult 

OMEGA for current repair charges. Have 

the following information available BEFORE 

contacting OMEGA:
1.  Purchase Order number to cover the COST  

  of the repair,
2.  Model and serial number of the product, and
3.  Repair instructions and/or specific problems  

  relative to the product.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE 

RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) 

NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING 

DELAYS). The assigned AR number should then be marked on the outside of the return package and on any 

correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent 

breakage in transit.

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a 

period of 

13 months

 from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace 

period to the normal 

one (1) year product warranty

 to cover handling and shipping time. This ensures 

that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service 

Department will issue an Authorized Return (AR) number immediately upon phone or written request. 

Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no 

charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, 

including but not limited to mishandling, improper interfacing, operation outside of design limits,  

improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of  

having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; 

or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating 

conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not  

limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However,  

OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for 

any damages that result from the use of its products in accordance with information provided 

by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the 

company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR  

REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF 

TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY 

AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF  

LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of  

OMEGA with respect to this order, whether based on contract, warranty, negligence,  

indemnification, strict liability or otherwise, shall not exceed the purchase price of the  

component upon which liability is based. In no event shall OMEGA be liable for 

 

consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic 

Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical 

applications or used on humans. Should any Product(s) be used in or with any nuclear installation or 

activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility 

as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify 

OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the 

Product(s) in such a manner.

Summary of Contents for PHTX-11

Page 1: ...e mail info omega com For latest product manuals www omegamanual info MODEL PHTX 11 pH Two Wire Transmitter TM Shop online at omega com User sGuide...

Page 2: ...pecifications without notice omega com info omega com Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Cana...

Page 3: ...n Table II 9 10 1 2 2 2 3 4 CALIBRATION 1 Calibration interval 5 2 Equipment required 5 3 Calibration procedure TECHNICAL INFORMATION 1 Controls 2 Operation PART IV OPERATION INSTRUCTION INSTALLATION...

Page 4: ...ms Ez ii 2onlA 12 to 80 VDC 1013 ohm 4 to MODEL PHTX 11 SPECIFICATIONS Spans Input Impedance Output Current Power Supply Load Resistor Linearity Temperature Coefficient Accuracy Repeatability Output m...

Page 5: ...can change the range of output signal by utilizing jumpers on one of the circuit boards and adjusting the zero and span pots The 4 to 20mA output can be for the full 0 to 14 pH level is constantly di...

Page 6: ...lculate the required power supply voltage from the following equation Minimum power supply voltage phillips head screws supplied The input probe connector is a BNC jack mounted on the input circuit bo...

Page 7: ...ected to this pair of pads Jumper mA output current level for the desired pH level it is used in conjunction with the range switch The Zero pot affects the output current only There is interaction bet...

Page 8: ...from the millivolt source or a pH 2OmA Remove the cover from the range switch and turn all switches Off l Input adjustments should not be made while the output is in an over current condition ie grea...

Page 9: ...n terminals Refer to Table I for the correct resistor and millivolt values Adjust the Zero for 4 h ZERO adjustments interact and require going back and forth between them Connect a millivolt source or...

Page 10: ..._ _ 7 i _ iI __ l I...

Page 11: ...4 9 118 3 124 2 128 2 136 2 144 1 74 0 3 9 108 4 72 0 5 68 0 9 64 1 2 62 13 59 15 54 1 9 0 0 8 74 0 3 72 0 5 68 0 9 64 12 59 15 62 13 54 19 i48 1 6 144 1 136 2 2 12a 124 2 i18 3 108 4 333 5 ___ L 204...

Page 12: ...1 v b...

Page 13: ...l O t 7 DIA HOLE EL CUT OUT TABLE II PAN...

Page 14: ...A if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to m...

Page 15: ...s M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U...

Reviews: