![background image](http://html1.mh-extra.com/html/omega/os4000-series/os4000-series_user-manual_4129895015.webp)
On the mV/Degree analog output models (OS4001-MV), the default output is 1 mV/°F. You can
change the output from 1 mV/°F to 1 mV/°C or vice versa by going through the Configuration menu
with Response time set for 25 msec or higher. At 1 msec response time, the output is fixed at 1 mV/°F.
Polymer Bolt Probe Assemblies
The Polymer Bolt probes are offered at Right angle with quick disconnect as
shown in Figure 13. They come in three standard models as listed below:
Model No.
Temperature Range
Cable Length
2108-650-RA-1
100 to 425°C (212 to 797°F)
0.3 m (1 Ft)
2108-650-RA-3
125 to 425°C (257 to 797°F)
0.9 m (3 Ft)
2108-650-RA-6
150 to 425°C (302 to 797°F)
1.8 m (6 Ft)
The standard Polymer Bolt Probe length is 6.5 inches, other lengths are available
upon request (3 to 12 inches).
Figure 13. 2108 Series Quick-Disconnect Polymer Probe
Main Operations
3
3-2
LABEL
FC CONNECTOR
1/2-20 UNF-2A
REQUIRED "WELL" MACHINING
LENGTH OF PROBE - 0.016 MIN.
(1/16)
45°
ø 13.081
(0.515)
1/2-20 UNF-2B
ø 10.79
(0.423)
ø 7.97
(0.314)
19.05
(0.750)
5.715 (0.225) MIN.
9.53 (0.375) MIN.
0.30 m, 0.91 m, 1.83 m
(1', 3', or 6')
165.1
(6.50)
ø 12.7
(0.50) DIA.
25.4
(1.00)
11.1
(0.436)
ø 7.8 (0.307)
5.3 (0.210)
DIMENSIONS mm (in)
ø = DIAMETER
COUPLING
NUT
O-RING
POLYMER
PROBE
FIBER CABLE WITH RIGHT ANGLE
BEND AND QUICK-DISCONNECT
NOTE: