background image

Quantec’s QT412 transmitters allow users to activate calls on a Quantec system. They have a typical
infrared  (IR)  transmitting  range  of  10  metres  (line  of  sight)  and  a  typical  radio  frequency  (RF)
transmitting range of approx. 60 metres, dependent on physical conditions / environmental factors.

Each  transmitter  has  two  IR  emitter
windows  (one  on  each  side  to  maximise
performance), two buttons (A & B) and a
retained ‘pull clip’.

Depending  on  the  model  purchased,
pressing  its  buttons,  or  activating  its  pull
clip, will generate the following levels of
call on compatible Quantec IR call points, IR
ceiling receivers and/or RF receivers.

Model No.

Button A

Button B

Pull Clip

QT412RXA 

Attack Call

Attack Call

Attack Call

QT412RXCA 

Standard Call

Standard Call

Attack Call

Note that different levels of call to those listed above can be generated, if required. However, to
do  this  the  transmitter  must  be  reconfigured  by  an  experienced  engineer  using  a  QT423
Configurator (see page 4 for details). Note these instructions explain how to use standard factory-
supplied QT412RXA and QT412RXCA transmitters only.

Approved Document No: DNU4120001 Rev 4 • Page 1 of 4 

RECONFIGURING THE TRANSMITTER (OPTIONAL)

The QT423 Configurator allows the operation of a QT412 range transmitter to be tailored to suit
the requirements of a specific site. It allows authorised engineers to:

(Note: The available level of calls available include Attendance, Standard Call, Presence, Help 
Required, Reset, Emergency and Attack. See 

COMPATIBILITY ISSUES

, below.)

•  Assign the level of call that will be triggered when the transmitter’s A button is pressed

•  Assign the level of call that will be triggered when the transmitter’s B button is pressed.

•  Assign the level of call that will be triggered when the transmitter’s pull clip is activated.

•  Set the transmitter’s A & B buttons so they only trigger a call when both are pressed at the same time. 

•  Turn the transmitter’s ‘confidence’ beeper on or off (for button A, B and/or the transmitter’s pull clip).

•  Turn the transmitter’s RF action on or off (for button A, B and/or the transmitter’s pull clip).

•  Set the transmitter’s transmission time to run continuously or to automatically switch off after 

a pre-determined time.

•  Set the transmitter’s User ID code (from 0 to 255). See 

COMPATIBILITY ISSUES

, below.

•  Assign the transmitter an RF Group Address (0 to 15) to match the set up of any Quantec RF 

receivers on the system and prevent inadvertent triggering of any local receivers.

•  Change the transmitter’s mode of IR transmission to ‘pulsed’ to suit Quantec IR receivers 

manufactured before 1/10/99 (see 

COMPATIBILITY ISSUES

, below).

Refer to Document No. DNU0423000 for further details about the Quantec Configurator.

QT412RXA / QT412RXCA TECHNICAL SPECIFICATION (FACTORY DEFAULTS)

Radio frequency  . . . . . . . . . . . . . (RF868.3 MHz - this product is license exempt as per EN 300 220)
RF Range  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 metres* 
Infrared  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 940 nm modulated @ 38 Khz 
Infrared Range  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 metres line of sight* 
Default transmission times on activation (autostop) . . . . . . . . . . . . . . . . IR = 45 secs; RF = 30 secs** 
Weight (including battery)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 grams 
Dimensions (main body) W x H x D  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 mm x 115 mm x 25 mm 
Pull clip actuation force  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 kg / 15 Newtons 
Battery.  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rechargeable NiMHydride (not user serviceable) 
* dependent on receiver, physical conditions and environmental factors. 
** In accordance with European regulatory standards. 

COMPATIBILITY ISSUES

THESE TRANSMITTERS ARE NOT COMPATIBLE WITH QUANTEC IR CALL POINTS, IR CEILING
RECEIVERS AND RF RECEIVERS MANUFACTURED BEFORE YEAR 2000.

THE NEW FEATURES, ‘USER ID’, ‘LOW BATTERY SIGNALS’ AND ‘ATTENDANCE’, DESCRIBED IN
THIS INSTRUCTION, WILL ONLY WORK ON COMPATIBLE QUANTEC SYSTEMS MANUFACTURED
AFTER 1 JULY 2010. IF IN DOUBT, PLEASE CONTACT YOUR VENDOR FOR ADVICE.

Errors and omissions excepted. These instructions are general and cannot be considered to cover every aspect of IR/RF transmitter
use. No responsibility can be accepted by the manufacturer or distributors of this equipment for any misinterpretation of an
instruction or guidance note or for the compliance of the system as a whole. The manufacturer of this equipment operates a policy
of continuous improvement and reserves the right to alter product specifications at its discretion and without prior notice.

QT412RXA / QT412RXCA

RECHARGEABLE DUAL-ACTION INFRARED / RADIO TRANSMITTER

Q

 

 

 

 

 

 

 

 

 

 

 

   

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

   

 

 

   

 

 

 

 

 

 

 

 

 

   

 

 

       

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

   

 

 

 

 

 

     

 

   

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

   

 

 

   

 

 

 

 

   

   

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

   

 

 

 

 

   

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

  

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

   

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IMPORTANT

• The transmitter must be charged for a period of 14 hours before it is first
used - see 

RECHARGING THE TRANSMITTER

, page 3.

• If  using  the  transmitter  with  an  existing  Quantec  system  please  refer  to

COMPATIBILITY ISSUES

, page 4.

 

 

 

 

 

 

 

 

 

 

 

   

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

   

 

 

   

 

 

 

 

 

 

 

 

 

   

 

 

       

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

   

 

 

 

 

 

     

 

   

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

   

 

 

   

 

 

 

 

   

   

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

   

 

 

 

 

   

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

  

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

   

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

PULL CLIP

MECHANISM

IR EMITTER

WINDOWS

PUSH

BUTTONS

MARKABLE

TEXT BOXES

READ ALL OF THESE INSTRUCTIONS BEFORE USING THIS TRANSMITTER

IF YOU INTEND TO USE THIS TRANSMITTER WITH AN 800 SERIES CALL SYSTEM,

REFER TO THE SEPARATE INSTRUCTION BOOKLET, DOCUMENT NO. DNU4120002.

Approved Document No: DNU4120001 Rev 4 • Page 4 of 4 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    

 

 

 

 

 

 

 

 

 

 

 

 

 

"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

"

 

 

 

 

 

 

 

 

 

 

 

 

  

   

 

 

 

 

 

   

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

   

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

   

   

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 