background image

OS35

 

Infrared Temperature Sensor 
Installation Instructions 

1.  Install OS35 as close as practical to view target material to be measured 
2.  Wire OS35 with Red to Positive Power, Black to Ground, White to Positive 

Output Signal, and Green to Reference Output Signal 

3.  Measure actual temperature of target material with OS950 Thermometer or 

any reliable reference 

4.  Adjust “offset”, “zero”, or “low cal” on input device to match reading to ac-

tual thermometer reading 

5.  Installation calibration complete 

 

*Six counts off one count on 
**Six counts on one count off 

ERROR MESSAGES

 

Condition

 

Priority

 

LED Display

 

0-5V

 

0-10V

 

4-20mA

 

RS-232

 

Low Power

 

1

 

OFF

 

Under 0.1V

 

Under 0.1V

 

Under 4mA

 

Not Implemented

 

Hardware Internal 

Errors

 

2, 13

 

Uniform Flash

 

Over 4.9V

 

Over 9.8V

 

Over 19.7mA

 

Not Implemented

 

Vsig-Offset High

 

3

 

Uniform Flash

 

Over 4.9V

 

Over 9.8V

 

Over 19.7mA

 

Not Implemented

 

Vsig-Offset Low

 

4

 

Uniform Flash

 

Over 4.9V

 

Over 9.8V

 

Over 19.7mA

 

Not Implemented

 

EMI

 

5

 

Uniform Flash

 

Over 4.9V

 

Over 9.8V

 

Over 19.7mA

 

Not Implemented

 

Range Error

 

6

 

Uniform Flash

 

Over 4.9V

 

Over 9.8V

 

Over 19.7mA

 

Not Implemented

 

High Ambient

 

7

 

Long Flash**

 

Over 4.9V

 

Over 9.8V

 

Over 19.7mA

 

Not Implemented

 

Low Ambient

 

8

 

Short Flash*

 

Over 4.9V

 

Over 9.8V

 

Over 19.7mA

 

Not Implemented

 

Too Much Heat 

Flow

 

9

 

Long Flash**

 

Over 4.9V

 

Over 9.8V

 

Over 19.7mA

 

Not Implemented

 

Too Little Heat 

Flow

 

10

 

Short Flash*

 

Over 4.9V

 

Over 9.8V

 

Over 19.7mA

 

Not Implemented

 

High Target

 

11

 

Long Flash**

 

Over 4.9V

 

Over 9.8V

 

Over 19.7mA

 

Not Implemented

 

Low Target

 

12

 

Short Flash*

 

Over 4.9V

 

Over 9.8V

 

Over 19.7mA

 

Not Implemented

 

(888) TC-OMEGA (USA/Canada) / (203) 359-1660 (International) 

Summary of Contents for OS35

Page 1: ...omega com e mail info omega com For latest product manuals omegamanual info User sGuide OS35 Series Smart Infrared Temperature Sensors Shop online at MADE IN OS35 20 OS35 3...

Page 2: ...n Germany TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 639 7678 e mail info omega de United Kingdom One Omega Drive River Bend Technology Centre ISO 9002 Certified Northbank Ir...

Page 3: ...ors due to leakage current in your input device Custom scaling and programming for low emissivity materials and low temperatures available OS35 3 3 1 FOV 3 71 x 1 37 x 0 76 94 3 x 34 9 x 19 4 mm OS35...

Page 4: ...nal Errors 2 13 Uniform Flash Over 4 9V Over 9 8V Over 19 7mA Not Implemented Vsig Offset High 3 Uniform Flash Over 4 9V Over 9 8V Over 19 7mA Not Implemented Vsig Offset Low 4 Uniform Flash Over 4 9V...

Page 5: ...no price change For RS232 output which is available only on 250 C range with 12 V power change MA to RS no price change Comes with air tubing Ordering Example 1 OS35 3 MA 100C 24V OS35 3 MA 100C 24V...

Page 6: ...m 0 625 15 9 mm Ambient Temperature Range 0 to 70 C 32 to 158 F Storage Temperature 10 to 70 C 14 to 158 F Construction Heavy Duty Alloy Casting Weight Approximately 8 oz 227 g Relative Humidity 95 no...

Page 7: ...ve Output Signal 6 Brown TA Pull Down Pin IO option 2 Green Reference Output Signal 7 Yellow RS232_TXD IO option 3 Red Positive Power 8 Violet RS232_RXD IO option 4 Black Ground 9 Blue RS232_RTD READY...

Page 8: ...C 1 8 F or 1 of reading at e 0 9 Recommended Power Supply 12 10 V DC or 24 10 V DC depending on model Power Accepted Shuts off when voltage is functionally low Power Consumption 12V power less then 40...

Page 9: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 10: ...ty Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial...