INSTALLATION INSTRUCTIONS 

The following procedure is recommended: 

1. 

Install the SmartIRt/c as close as practical to view the target material to be 
measured. 

2. 

Wire the SmartIRt/c to the controller, PLC, etc. in standard fashion (see PIN-
OUT and wiring diagram) 

3. 

Bring the process up to normal operating temperature and measure the actual 
temperature of the target material with the Microscanner D-Series, DX-Series 
Infrared Thermometer or any other reliable reference.  

4. 

Adjust "input offset," "zero," "low cal," on the readout device to match the  
reading of your reference. 

Installation Complete. (For OEM installations preset the same adjustments. Indi-
vidual calibration is not required.) 

PIN OUT

 

Carol C074 Series/Belden 953 Series/Alpha 630 Series

 

 
Pin

 

Color

 

Function

 

Pin

 

Color

 

Function

 

1

 

White

 

Positive Output Signal

 

6

 

Brown

 

TA Pull Down Pin / IO option

 

2

 

Green

 

Reference Output Signal

 

7

 

Yellow

 

RS232_TXD / IO option

 

3

 

Red

 

Positive Power

 

8

 

Violet

 

RS232_RXD / IO option

 

4

 

Black

 

Ground

 

9

 

Blue

 

RS232_RTD (READY_TO_SEND)

 

5

 

Bare

 

Shield

 

10

 

Orange

 

RS232_CTS (CLEAR_TO_SEND)

 

WIRING DIAGRAM 

ORDERING INFORMATION 

SmartIRt/c-

F-P-O-T or  

Smart-microIRt/c

-F-P-O-T (

F is -. .SV, .4, .4SV only for Smart-microIRt/c

FIELD OF VIEW 

POWER   

OUTPUT         

T      

TEMPERATURE RANGE 

.3 

3:1 

 

12V 

12 VDC   

05 

0-5V 

     

100C         

0-100C   

.5 

5:1 

 

24V 

24 VDC   

010 

0-10V 

     

250C         

0-250C   

.20 

20:1 

 

 

 

 

420 

4-20 mA           

500C         

0-500C   

.40 

40:1 

 

 

 

 

232 

RS232 

     

1000C       

0-1000C 

- 1:2 

       70C 

 -30-70C 

.SV 1:2 
.4 4:1 
.4SV 4:1 

OPTION: 

Add Ta to any part # to add ambient temperature option to output ambient temperature surrounding sensor 

 

NOTE: 

0-10V only available in 24VDC and RS232 only available in 12VDC from 0-250C 

 
Examples: 

SmartIRt/c.3-24V-420-250C (3:1 field of view, 24VDC power, 4-20mA output from 0-250C),  

Smart-microIRt/c-12V-05-250C (1:2 field of view, 12VDC power, 0-5V output from 0-250C). or  
SmartIRt/c.3-24V-420-250C-Ta (with 4-20mA outputting target temperature and ambient temperature from 0-250C)      

 



 

Summary of Contents for OS35

Page 1: ...omega com e mail info omega com For latest product manuals omegamanual info User sGuide OS35 Series Smart Infrared Temperature Sensors Shop online at MADE IN OS35 20 OS35 3...

Page 2: ...n Germany TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 639 7678 e mail info omega de United Kingdom One Omega Drive River Bend Technology Centre ISO 9002 Certified Northbank Ir...

Page 3: ...ors due to leakage current in your input device Custom scaling and programming for low emissivity materials and low temperatures available OS35 3 3 1 FOV 3 71 x 1 37 x 0 76 94 3 x 34 9 x 19 4 mm OS35...

Page 4: ...nal Errors 2 13 Uniform Flash Over 4 9V Over 9 8V Over 19 7mA Not Implemented Vsig Offset High 3 Uniform Flash Over 4 9V Over 9 8V Over 19 7mA Not Implemented Vsig Offset Low 4 Uniform Flash Over 4 9V...

Page 5: ...no price change For RS232 output which is available only on 250 C range with 12 V power change MA to RS no price change Comes with air tubing Ordering Example 1 OS35 3 MA 100C 24V OS35 3 MA 100C 24V...

Page 6: ...m 0 625 15 9 mm Ambient Temperature Range 0 to 70 C 32 to 158 F Storage Temperature 10 to 70 C 14 to 158 F Construction Heavy Duty Alloy Casting Weight Approximately 8 oz 227 g Relative Humidity 95 no...

Page 7: ...ve Output Signal 6 Brown TA Pull Down Pin IO option 2 Green Reference Output Signal 7 Yellow RS232_TXD IO option 3 Red Positive Power 8 Violet RS232_RXD IO option 4 Black Ground 9 Blue RS232_RTD READY...

Page 8: ...C 1 8 F or 1 of reading at e 0 9 Recommended Power Supply 12 10 V DC or 24 10 V DC depending on model Power Accepted Shuts off when voltage is functionally low Power Consumption 12V power less then 40...

Page 9: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 10: ...ty Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial...

Reviews: