OM-CP-ULTRASHOCK-A  & OM-CP-SHOCK300 

OM-CP-ULTRASHOCK-A Specifications

Battery Warning

FIRE, EXPLOSION AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CRUSH, PENETRATE, INCINERATE OR DISASSEMBLE. AVOID 

TEMPERATURES ABOVE THE MAXIMUM OPERATING TEMPERATURE OF THE PRODUCT. DISPOSE OF PROPERLY. CHARGE ONLY WITH THE 

PROVIDED OMEGA CHARGER, OR FROM OTHER USB POWER SOURCE VIA THE OMEGA PROVIDED CABLE. 

Specifications subject to change.

See Omega’s terms and conditions at www.omega.com

TEMPERATURE

Sensor

Semiconductor

Range

-20 ºC to +60 ºC

Resolution

0.1 ºC

Accuracy

±0.5 °C (+5 °C to +60 °C)

HUMIDITY

Sensor

Capacitive Polymer

Range

0 %RH to 95 %RH

Resolution

0.1 %RH

Calibrated  

Accuracy

±3 %RH (±2 %RH typical at 25 ºC)

Specified  

Accuracy Range

+20 °C to +40 °C; 25 %RH to 75 %RH

PRESSURE

Sensor

Semiconductor Strain Gage

Range

100 mbar to 1300 mbar

Resolution

0.05 mbar

Calibrated  

Accuracy

±1.5 mbar at 25 ºC; at 750 mbar

SHOCK

Accelerometer 

Type

MEMS Semiconductor

Acceleration  

Range (g)

±15 g

±100 g

±300 g

Acceleration 

Resolution (g)

0.02 g

0.05 g

0.2 g

Calibrated  

Accuracy (g)

±0.3 g

±2.0 g

±6.0 g

Sampling Rate

1000 Hz

Accelerometer 

Freq. Resp.

>1000 Hz (15 g)

>500 Hz (100 g, 300 g)

Reading Rate

1024 Hz to 5 minutes for shock, 

selectable in software. Temperature, 

pressure and humidity sampled  

approx. every 2 seconds at intervals 

shorter than 2 seconds. Otherwise, 

sampled at the reading rate.

GENERAL

Memory

3,593,358 readings (598,893 per 

channel, all channels in use)

Start Modes

Software programmable immediate 

start or delay start, up to 6 months in 

advance

Real Time  

Recording

May be used with PC to monitor and 

record data in real time at a 1 second 

sample rate

Password  

Protection

An optional password may be 

programmed into the device to restrict 

access to configuration options. Data 

may be read out with the password.

Calibration

Digital calibration through software

Calibration Date

Automatically recorded within device

Battery Type

Internal Lithium Ion pack, charger 

included

Battery Life

90 days typical at 64Hz rate

Data Format

Date and time stamped gravities (g 

and mg), temperature (°C, °F, K, °R), 

humidity (%RH, mg/ml water vapor 

concentration), pressure (PSIA, inHg, 

mmHg, bar, atm, Torr, Pa, kPa, MPa)

IP Rating

IP64

Time Accuracy

10 seconds/month (at 0 ºC to 50 ºC)

Computer  

Interface

USB-C cable required (included); 

1MBaud

Supported 

Software

Windows XP SP3/7/8/10

Software 

Compatibility

Standard Software version 4.2.15.0 or 

later

Secure Software version 4.2.14.0 or 

later

Operating  

Environment

-20 ºC to +60 ºC,

0 %RH to 95 %RH non-condensing

Dimensions

3.4 in x 1.7 in x 1.3 in

(86 mm x 43 mm x 33 mm)

Weight

8 oz (227 g)

Enclosure

Anodized aluminum

Approvals

CE compliant

EMC Directive 2014/30/EU

RoHS Directive 2011/65/EU

Summary of Contents for OM-CP-SHOCK300

Page 1: ...and Tri Axial Shock Data Logger OM CP SHOCK300 Tri Axial Shock Data Logger MQS5089 0120 Xxxxx Xxxxxx Xxxxx Xxxxxx Xxxxxxxx M0000 0016 INSTRUCTION SHEET Shop online at omega comSM e mail info omega com For latest product manuals www omegamanual info TM ...

Page 2: ...lies the most recent custom start options Batch Start is used for managing multiple loggers at once Real Time Start stores the dataset as it records while connected to the logger The status of the device will change to Running Waiting to Start or Waiting to Manual Start depending upon your start method 5 Disconnect the data logger from the interface cable and place it in the environment to measure...

Page 3: ...g accelerometer 100g and 300g high g accelerometer Physical Mounting The most accurate transfer of shock vibration and acceleration to the final logged data will occur when the mounting is mechanically rigid Typically this would occur when the OM CP ULTRASHOCK A and OM CP SHOCK300 are mounted by two bolts directly to a solid metal flat surfaced object of significant mass For various applications t...

Page 4: ...hout USB connected and adequate battery charge level Flashes every 15 seconds maximum Indicates low battery charge level Logging Data with USB communication Flashes every 15 seconds Indicates normal operation of logger with USB connected Flashes every 5 seconds maximum Indicates when logger communication occurs via USB Delayed Logging Start Flashes every 3 seconds Red and green LED indicators simu...

Page 5: ...elay in response time to humidity and temperature measurements as the OM CP ULTRASHOCK A processes shock events before other parameters Pressure The OM CP ULTRASHOCK A pressure sensor is designed to measure barometric pressure from very low altitudes to those altitudes found in aircraft up to high altitude balloons While specified to 300 mbar it will continue to report data to 100 mbar This equate...

Page 6: ...only sample data at the logging rate For instance if a 30 second logging rate was selected then only a single data point is captured at each 30 second instant The potential to lose valuable data can be seen This of course is very dependent on the applied shock duration and wave shape It s possible for a significant shock event to occur and not even be visible in the data for the Instantaneous mode...

Page 7: ...ired at the selected logging rate The trigger sample count should be chosen carefully because it may gather data points for which we have no interest For instance if 100 were entered and the logging rate were 30 seconds then 100 data points would be gathered over a 3 000 second interval There may be very little relevant information to a shock event which triggered the logging process While the use...

Page 8: ... only used for the duration of the triggered shock events plus a post event buffer which is user programmable Product Maintenance Battery Charging and Care The OM CP ULTRASHOCK A and OM CP SHOCK300 battery do not require any periodic maintenance It should be charged as needed If the unit will not be used for a while leaving the battery in a 50 state of charge is considered beneficial to battery lo...

Page 9: ...humidity sampled approx every 2 seconds at intervals shorter than 2 seconds Otherwise sampled at the reading rate GENERAL Memory 3 593 358 readings 598 893 per channel all channels in use Start Modes Software programmable immediate start or delay start up to 6 months in advance Real Time Recording May be used with PC to monitor and record data in real time at a 1 second sample rate Password Protec...

Page 10: ... Time Recording May be used with PC to monitor and record data in real time at a 1 second sample rate Password Protection An optional password may be programmed into the device to restrict access to configuration options Data may be read out with the password Calibration Digital calibration through software Calibration Date Automatically recorded within device Battery Type Internal Lithium Ion pac...

Page 11: ... a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnif...

Reviews: