LED Indicator Functions

The red and green LEDs on the front of the OM-CP-
ULTRASHOCK-A and OM-CP-SHOCK300 will flash or maintain 
a static condition to represent operating functions as shown 
in the table below.

The power up indication is only presented if the battery pack 
is separated from the front face and replaced. This should be 
done only during factory service or if directed to do so by a 
Omega support or repair agent. If it is presented at any other 
time, there may be a malfunction of the unit.

OM-CP-ULTRASHOCK-A & OM-CP-SHOCK300 

Red LED 

Indicator

Green LED 

Indicator

OPERATING FUNCTION

GREEN LED INDICATOR

RED LED INDICATOR

Power-up Indicator

Flashes 4 times

 

Red and green LED indicators alternately and rapidly flash 4 times each at power-up. LED 

indicators continue to flash for error at power-up.

Logging Data  

(without USB connected)

Flashes every 15 seconds

 

Indicates normal operation of logger without 

USB connected and adequate battery charge 

level.

Flashes every 15 seconds (maximum) 

Indicates low battery charge level.

Logging Data 

(with USB communication)

Flashes every 15 seconds

 

Indicates normal operation of logger with USB 

connected.

Flashes every 5 seconds (maximum)

 

Indicates when logger communication occurs 

via USB.

Delayed Logging Start

Flashes every 3 seconds

 

Red and green LED indicators simultaneously flash every 3 seconds to indicate data logging 

delayed start is set.

USB Charging 

(USB connected)

Pulses slowly on and off

 

Indicates when battery is charging via USB 

connector.

Flashes every 5 seconds (maximum)

 

Indicates when logger communication occurs 

via USB.

Battery Charged 

(USB connected)

On

 

Indicates when battery is fully charged when 

connected to USB.

Flashes every 5 seconds (maximum)

 

Indicates when logger communication occurs 

via USB.

Battery Charging Fault 

(USB connected)

Off

 

On 2 seconds then off 2 seconds

 

Indicates when there is a battery charging fault 

and continues to flash until fault is cleared.

Logger Off

Off

 

Red and green LED indicators are off when logger is off and USB not connected.

Summary of Contents for OM-CP-SHOCK300

Page 1: ...and Tri Axial Shock Data Logger OM CP SHOCK300 Tri Axial Shock Data Logger MQS5089 0120 Xxxxx Xxxxxx Xxxxx Xxxxxx Xxxxxxxx M0000 0016 INSTRUCTION SHEET Shop online at omega comSM e mail info omega com For latest product manuals www omegamanual info TM ...

Page 2: ...lies the most recent custom start options Batch Start is used for managing multiple loggers at once Real Time Start stores the dataset as it records while connected to the logger The status of the device will change to Running Waiting to Start or Waiting to Manual Start depending upon your start method 5 Disconnect the data logger from the interface cable and place it in the environment to measure...

Page 3: ...g accelerometer 100g and 300g high g accelerometer Physical Mounting The most accurate transfer of shock vibration and acceleration to the final logged data will occur when the mounting is mechanically rigid Typically this would occur when the OM CP ULTRASHOCK A and OM CP SHOCK300 are mounted by two bolts directly to a solid metal flat surfaced object of significant mass For various applications t...

Page 4: ...hout USB connected and adequate battery charge level Flashes every 15 seconds maximum Indicates low battery charge level Logging Data with USB communication Flashes every 15 seconds Indicates normal operation of logger with USB connected Flashes every 5 seconds maximum Indicates when logger communication occurs via USB Delayed Logging Start Flashes every 3 seconds Red and green LED indicators simu...

Page 5: ...elay in response time to humidity and temperature measurements as the OM CP ULTRASHOCK A processes shock events before other parameters Pressure The OM CP ULTRASHOCK A pressure sensor is designed to measure barometric pressure from very low altitudes to those altitudes found in aircraft up to high altitude balloons While specified to 300 mbar it will continue to report data to 100 mbar This equate...

Page 6: ...only sample data at the logging rate For instance if a 30 second logging rate was selected then only a single data point is captured at each 30 second instant The potential to lose valuable data can be seen This of course is very dependent on the applied shock duration and wave shape It s possible for a significant shock event to occur and not even be visible in the data for the Instantaneous mode...

Page 7: ...ired at the selected logging rate The trigger sample count should be chosen carefully because it may gather data points for which we have no interest For instance if 100 were entered and the logging rate were 30 seconds then 100 data points would be gathered over a 3 000 second interval There may be very little relevant information to a shock event which triggered the logging process While the use...

Page 8: ... only used for the duration of the triggered shock events plus a post event buffer which is user programmable Product Maintenance Battery Charging and Care The OM CP ULTRASHOCK A and OM CP SHOCK300 battery do not require any periodic maintenance It should be charged as needed If the unit will not be used for a while leaving the battery in a 50 state of charge is considered beneficial to battery lo...

Page 9: ...humidity sampled approx every 2 seconds at intervals shorter than 2 seconds Otherwise sampled at the reading rate GENERAL Memory 3 593 358 readings 598 893 per channel all channels in use Start Modes Software programmable immediate start or delay start up to 6 months in advance Real Time Recording May be used with PC to monitor and record data in real time at a 1 second sample rate Password Protec...

Page 10: ... Time Recording May be used with PC to monitor and record data in real time at a 1 second sample rate Password Protection An optional password may be programmed into the device to restrict access to configuration options Data may be read out with the password Calibration Digital calibration through software Calibration Date Automatically recorded within device Battery Type Internal Lithium Ion pac...

Page 11: ... a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnif...

Reviews: