Product Overview

The OM-CP-RFC1000-EXT, a high powered transceiver that has a substantially long transmission range, 
providing enhanced performance in occluded environments (ovens, refrigerators, etc.). The OM-CP-RFC1000-
EXT also features an external antenna, allowing more flexibility with mounting positions in both orientation 
and proximity to metal walls. The device may be used as a repeater, or directly plugged into the Windows PC.

 

Transmission Distance

The OM-CP-RFC1000-EXT transmits to other OM-CP-RFC1000-EXTs up to 4000 feet maximum typical 
outdoors/line of sight, 1000 feet maximum typical indoors/urban. The OM-CP-RFC1000-EXT transmits to data 
loggers up to 2000 feet maximum typical outdoors/line of sight, 500 feet maximum typical indoors/urban. 
The OM-CP-RFC1000-EXT can connect to a maximum of 64 data loggers. The OM-CP-RFC1000-EXT transmits 
on a frequency of 2.405GHz - 2.475 GHz.

Operating Environment

The OM-CP-RFC1000-EXT is rated for use in an environment with temperatures from -20°C to 85°C and a 
humidity range of 0% to 95% RH non-condensing. The OM-CP-RFC1000-EXT is rated IP40 and is protected 
against solids that are greater than 1mm in size. This device is not water resistant.

LEDs

The red LED indicates that the device has power. The green LED will blink when communicating with other 
MadgeTech devices.

Installation Guide

Installing the Omega Data Logger Software

Insert the Omega Software Flash Drive into an open USB port on a Windows PC. 
If the autorun does not appear, locate the drive on the computer and double 
click on 

Autorun.exe

. Follow the instructions provided in the Installation Wizard. 

Software can also be downloaded from the Omega website.

1.  Locate the 

Autorun.exe

 file on the Omega Software Flash Drive. 

2.  Select 

“Omega Software”

 in the Omega Installer Options window panel. 

3.  If the Windows PC doesn’t already have .NET 4.0 Framework, installation may be required. 

Note: 

To see if the .NET 4.0 Framework is installed, go to the Windows Control Panel and select Programs. 

“Microsoft .NET Framework 4.0” 

would be listed as a Windows program. 

4.  Select 

“Install Omega Software”

 if .NET framework is installed on the Windows PC, or if installing on a 

Windows 8 machine.

Summary of Contents for OM-CP-RFPULSE2000A

Page 1: ...OM CP RFPULSE2000A Wireless Pulse Data Logger...

Page 2: ...er long periods of time Selection Buttons The logger is designed with 3 direct selection buttons Scroll Units and Wireless Scroll Allows user to scroll through information displayed on the LCD Screen...

Page 3: ...Stop icon and then click the Download icon A graph will automatically display the data Product Operation Plugged In Install the Omega Software and USB Drivers onto a Windows PC Before plugging the da...

Page 4: ...and text message notifications will not be received if settings are incorrect 5 Click OK The OK button will be disabled if the Rule name box is empty Changing the Alarm Settings of a Device 1 In the...

Page 5: ...ata logger is not appearing in the Connected Devices list it may be that the OM CP RFC1000 EXT is not properly connected 1 In the software click the File button then click Options 2 In the Options win...

Page 6: ...erials OM CP BAT103 1 On the bottom of the enclosure open the battery compartment by pulling in on the cover tab 2 Remove the battery by pulling it from the compartment 3 Install the new battery takin...

Page 7: ...Weight 4 1 oz 0 2563 lbs Enclosure Material ABS Plastic Alarm User configurable audible on screen email and text SMS alarms Alarm Delay A cumulative alarm delay may be set in which the device will ac...

Page 8: ...onment OM CP RFC1000 EUR 2 500 max outdoors line of sight unobstructed 700 max indoors typical urban environment OM CP RFC1000 IP69K 4 000 max outdoors line of sight unobstructed 1 000 max indoors typ...

Page 9: ...Quick Start Manual OM CP RFC1000 EXT Wireless Transceiver Other models available OM CP RFC1000 EUR Approved for European markets OM CP RFC1000 IP69K Splash Proof for harsh environments...

Page 10: ...ures from 20 C to 85 C and a humidity range of 0 to 95 RH non condensing The OM CP RFC1000 EXT is rated IP40 and is protected against solids that are greater than 1mm in size This device is not water...

Page 11: ...performance both the OM CP RFC1000 EXT and the Omega data loggers should be mounted in the same orientation This usually means that the external antenna should be pointing straight up The antenna can...

Page 12: ...The images below show the orientations available of the switches for each channel Channel 26 all switches in the up position is not supported Follow the instructions below to configure the channel set...

Page 13: ...eless mode by holding down the Wireless button for 5 seconds Deploying and Activating Devices 1 Plug the OM CP RFC1000 EXT into the USB port on the base station computer Additional OM CP RFC1000 EXTs...

Page 14: ...ata logger is not appearing in the Connected Devices list it may be that the OM CP RFC1000 EXT is not properly connected 1 In the software click the File button then click Options 2 In the Options win...

Page 15: ...Antenna 7 2 Approvals FCC ID OA3MRF24J40MC IC 7693A 24J40MC Transmission Distance To other OM CP RFC1000 EXTs 4000 max outdoor line of sight unobstructed 1000 max indoors typical urban environment Tr...

Page 16: ...forme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l ut...

Page 17: ...l application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA...

Reviews: