OM-CP-HITEMP140-FP

Battery Warning

WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, 

PENETRATE OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 80 °C (176 °F).

Specifications subject to change. 

See Omega’s terms and conditions at www.omega.com

Temperature Sensor Flexible RTD Probe

Probe Range -60°C to +260°C (-76°F to +500°F)

Temperature Resolution 0.01°C (0.02°F)

Calibrated Accuracy ±0.1°C (0.18°F)

Memory 32,767 readings

Number of Readings in

Trigger Settings Mode 10,922 readings

Reading Rate 1 reading every 0.25 seconds up to 1 reading every 24 hours

Required Interface Package OM-CP-IFC400 or OM-CP-IFC406 USB docking station required

Baud Rate 125,000 baud

Typical Battery Life 1 year typical (1 minute reading rate at 25°C/ 77°F)

Operating System

Compatibility XP SP3/Vista/Windows 7/Windows 8

OM-CP Software

Compatibility

•  OM-CP Standard Software version 4.2.1.1

•  OM-CP Secure Software version 4.2.0.1 or later

Operating Environment -40°C to +140°C (-40°F to +284°F) 0%RH to 100%RH

Material •  Body: 316 Stainless Steel

•  Probe: PFA Insulated Cable

Dimensions (Body) 2.95” x 0.97” x 0.97” (75mm x 24.6mm x 24.6mm)

Dimensions (Probe) •  OM-CP-HITEMP140-FP-36: 36” x 0.10” (914mm x 2.5mm)

•  OM-CP-HITEMP140-FP-72: 72” x 0.10” (1829mm x 2.5mm)

Weight 85g (3oz)

Submersible Yes (IP68)

Approvals CE

OM-CP-HITEMP140-FP General Specifications

6

Summary of Contents for OM-CP-HITEMP140-FP

Page 1: ...OM CP HITEMP140 FP High Temperature Data Logger with Flexible RTD Probe e mail info omega com For latest product manuals www omegamanual info Shop online at omega com User sGuide TM...

Page 2: ...ry becomes discharged The OM CP HITEMP140 FP can be configured for delayed start and is capable of reading rates as often as four readings per second up to once every 24 hours Submergibility The OM CP...

Page 3: ...IFC400 is not properly connected 1 In the software click the File button then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all of the available c...

Page 4: ...ther parameters appropriate for the data logging application and click Start Quick Start applies the most recent custom start options Batch Start is used for managing multiple loggers at once Real Tim...

Page 5: ...he pervasive nature of pressurized steam creates a very difficult environment for electronics Please refer to the following preventative maintenance procedure when using this device in steam steriliza...

Page 6: ...nds up to 1 reading every 24 hours Required Interface Package OM CP IFC400 or OM CP IFC406 USB docking station required Baud Rate 125 000 baud Typical Battery Life 1 year typical 1 minute reading rate...

Page 7: ...ion or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way OME...

Reviews: