background image

 

 

   

               APPLIANCE DETAILS

 

   

                  WIRING DIAGRAM

 

 

BURNERS

 

 
 

GAS

 

 

NORMAL 

PRESSURE

 

 

KPa

 

 

INJECTOR 

DIAMETER

 

 

1/100 mm

 

TAPE BY 

PASS 

DIAMETER

 

1/100 mm

 

 

NOMINAL 

HEAT INPUT

 

(MJ/h)

 

 

DESCRIPTION

 

 

1

 

 

RAPID

 

Universal LPG

 

Natural

 

2.75

 

1.00

 

85

 

15

40

 

Adjust.

 

9.6

 

11.5

 

 

2

 

 

SEMI-RAPID

 

Universal LPG

 

Natural

 

2.75

 

1.00

 

65

 

110

 

31

 

Adjust.

 

5.6

 

6.3

 

 

3

 

 

AUXILIARY

 

Universal LPG

 

Natural

 

2.75

 

1.00

 

52

 

80

 

27

 

Adjust.

 

3.4

 

3.4

 

 

4

 

TRIPLE 

CROWN

 

Universal LPG

 

Natural

 

2.75

 

1.00

 

95

 

16

60

 

Adjust.

 

12.0

 

13.0

 

 

5

 

DOUBLE 

CROWN

 

Universal LPG

 

Natural

 

2.75

 

1.00

 

98

 

16

60

 

Adjust.

 

12.5

 

12.5

 

 

 
 
MODEL: OCG63FXB1                          MODEL: OCG75FXB/ OCG90FXB

 

 

 

 

 

 

 

 

 

 

 

IGNITION 
GENERATOR 

IGNITION 
GENERATOR 

TRIPOLAR 
TERMINAL 

TRIPOLAR 
TERMINAL 

MICRO-UNIT 

MICRO-UNIT 

11

 

L N

 

Summary of Contents for OCG63FXB1

Page 1: ...INSTRUCTIONS FOR THE INSTALLATION AND USE OF BUILT IN HOT PLATES OCG63FXB1 OCG75FXB OCG90FXB...

Page 2: ......

Page 3: ...the manufacturer or its service agent Before carrying out the maintenance or cleaning the equipment cut off power supply and allow it cool down Make sure that air circulates around the gas equipment...

Page 4: ...itions must be chosen between the maximum and the minimum ones never between the minimum position and the closing point The gas supply can be interrupted by turning the knob clockwise up to the closin...

Page 5: ...is obtained when control knob is activated Electricity supply is disconnected or switched off Switch on electricity or check fuses Ignition spark plugs wet or dirty Dry or clean ignition spark plugs F...

Page 6: ...e sure that the flame dividing ducts are not clogged Check that the feeler of the safety valve and the start up electrode are always cleaned so as to ensure optimum operation Gas taps The possible lub...

Page 7: ...er if the hob is going to be installed on the top of a built in oven without forced cooling ventilation proper air vents must be installed to guarantee an adequate ventilation with the lower air enter...

Page 8: ...nd the sealing washer is placed between the manifold end and the flat face on the elbow The tapered thread connects to the outlet of the regulator and is sealed on the thread using approved thread sea...

Page 9: ...ors to replace must be made according to the table of the technical characteristics as enclosed Act as follows Remove the racks and burners By means of a straight spanner L unscrew the injectors U fig...

Page 10: ...OFF MAXIMUM MINIMUM 1 2 3 4 5 6 9 7 8 8A 9A F F 9...

Page 11: ...Rapid burner 11 5 MJ h 9 6 MJ h 2 Semi rapid burner 6 3 MJ h 5 6 MJ h 3 Auxiliary burner 3 4 MJ h 3 4 MJ h 4 Triple ring burner 13 0 MJ h 12 0 MJ h 5 Double ring burner 12 5 MJ h 12 5 MJ h 8 Control...

Page 12: ...2 SEMI RAPID Universal LPG Natural 2 75 1 00 65 110 31 Adjust 5 6 6 3 3 AUXILIARY Universal LPG Natural 2 75 1 00 52 80 27 Adjust 3 4 3 4 4 TRIPLE CROWN Universal LPG Natural 2 75 1 00 95 16 60 Adjust...

Page 13: ...RIVET The mini trivet included with this cooktop is to be used for cooking vessels of diameter 120mm or smaller Incorrect fitment Correct fitment Examples of positioning of mini trivet MODEL OCG63FXB1...

Reviews: