7
Electrical Connections
LOCAL AUTHORITY REQUIREMENTS
Installation is only permitted by a licensed electrician and carried out according to
instructions provided by the manufacturer. Incorrect installation might cause harm and
damage which the manufacturer accepts no responsibility.
ELECTRICAL INSTALLATION FOR THE LICENSED ELECTRICIAN
This oven must be connected to a 220-240V 50Hz power supply.
Before carrying out the connection to the power supply, the voltage rating of the appliance
(stamped on the appliance identification plate) must be checked for correspondence to the
available mains supply voltage, and the mains electric wiring should be suitable for the oven’s
power rating (also indicated on the appliance identification plate);
The switched outlet must be connected to a suitable earth wiring, in conformity to current safety
regulations.
A circuit breaker with a contact opening of at least 3mm MUST be installed inside the supply
circuit. It should not be located above the appliance and no more than 1.25m away from it. The
power supply cord must not touch any hot surfaces and must be placed so that its temperature
does not exceed 75°C at any point along its length. After having installed the appliance, the
switched outlet must always be in an accessible position.
NOTE
: For connections to the mains power supply, never use adapters, reductions or multiple
power points as these may overheat and catch fire.
The mains terminal block is located on the back of the oven and the terminals are accessible by
opening the terminal block cover.
Note
: The terminal cover should not be opened when the mains power is still connected to the
appliance and never by an unauthorized person.
The electrical safety of this appliance can only be guaranteed if the oven is correctly and efficiently
earthed. The manufacturer declines all responsibility for damage resulting from an installation
which has not been earthed correctly. The use of adapters, multiple sockets and/or extensions, is
not allowed.