4.3.4 Sensor Parameters (continued)
Remote Display Format:
Remote display format is used for Terminal Server continuous
mode. This determines the data format sent by the iServer to a remote network node (e.g.
iLD Display)
H37.9%
in humidity setting displays
H
, and
37.9%
is the humidity value displayed.
Example: if the humidity is
37.9
, then
H37.9%
will be seen on the remote display. If no
format is specified (blank), there is no reading sent out. If temperature is
75.7
and
T00.0F
is used in temperature setting, the remote site will show
T75.7F
.
This format setup was originally made for the iLD Display, which has four or six LEDs.
For six LEDs,
T00.00F
format, and for four LEDs,
00.0F
format are appropriate.
Remote End Char:
The default value is 0D (Hex representation of <CR>). This means
that the iServer sends <CR> after each temperature, humidity, pressure, and dewpoint
value. This will be done either in Continuous or Command mode.
This is how the data will appear on the host with
0D assigned:
T75.7F
P1014.8mbar
H37.9%
D44.9F
If the end character for instance is 20 (Hex
representation of space), the data will then appear
as:
T75.7F P1014.8mbar H37.9% D44.9F
If nothing is set for the “Remote End Char” field,
the iServer will then forward the data to the LAN
with no characters followed.
Offset:
Since the sensing probe is solid state electronics, there is no need for
calibration. If it’s determined that the readings are slightly off, the user can manually
assign numerical values to adjust the readings for temperature, humidity, pressure, and
dewpoint. For temperature offset, the unit must be in degree C. The Offset value can
either be a positive or negative number
4.3.5 Configure Access Control
This section describes the "Access Control" page of the iServer’s Web interface. This
page allows the users to set up the network and security parameters of the iServer.
At the initial entrance to the “Access Control” page you will be prompted for the LOGIN
Password (see
Figure 4.6
) prior to an ADMINISTRATOR Password.
T75.7F
P1014.8mbar
H37.9%
D44.9F
T75.7F
P1014.9mbar
H37.9%
D44.9F
T75.7F
P1014.9mbar
H38.0%
D44.9F
Tera Term - 206.29.25.27 VT
File Edit Setup Control Window Help
Figure 4.11
Remote End Char