background image

TITLE

Main Menu

Title

(1 Day/Div)

1 Day

1 Month

1 Week

1 Month
1 Year

1 Minute

1 Hour

Wed Jun 01 12:00:00 PDT 2005

0

5/Div

50

Temp.

0015.7

300

90/Div

0%

100%

hPa

1200

RH 

Pres.

0040.9

1020.8

0005.7

C

Temp_RH_hPa

Tue Jun 28 12:00:00 PDT 2005

Dew.

http://192.168.1.200

Barometric Pressure,

Tempe Humidity

and

User’s Guide

omega.com  

e-mail: [email protected]

For Latest Product Manuals

omegamanual.info

®

®

Shop on line at

Summary of Contents for iBTX

Page 1: ...PDT 2005 0 5 Div 50 Temp 0015 7 300 90 Div 0 100 hPa 1200 RH Pres 0040 9 1020 8 0005 7 C Temp_RH_hPa Tue Jun 28 12 00 00 PDT 2005 Dew http 192 168 1 200 Barometric Pressure Temperature Humidity and U...

Page 2: ...is document is believed to be correct but OMEGA Engineering Inc accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These products are...

Page 3: ...ing a new IP Address over the Network 15 4 3 Setup and Operation using a Web Browser 16 4 3 1 Read Sensor 17 4 3 1 1 Java Runtime Environment 1 4 Setup Instructions 17 4 3 1 2 Java Runtime Environment...

Page 4: ...e iServer from MS DOS Prompt 12 Figure 4 2 Assigning an IP Address using iConnect 13 Figure 4 3 Accessing the iServer for Configuration 13 Figure 4 4 Access Control 15 Figure 4 5 iServer Home Page Men...

Page 5: ...t to successfully setup and use the iServer CAUTION or WARNING Tells you about the risk of electrical shock CAUTION WARNING or IMPORTANT Tells you of circumstances or practices that can affect the ins...

Page 6: ...ic Pressure Temperature Humidity with a Web Browser The iServer transmitter let s you monitor and record Barometric Pressure Temperature Relative Humidity and Dew Point over an Ethernet network or the...

Page 7: ...All iServer models that are on a LAN that is connected to the Internet can trigger an alarm that can be sent by email to a single user or to a group distribution list including text messages to cell p...

Page 8: ...nting Wall Mount iServer It is recommended that you ground your unit With one end of a wire connected to earth ground the other side can be wrapped around the ground screw located on the bottom of the...

Page 9: ...mounting slot onto DIN Rail as shown b Push unit towards DIN Rail and it will snap into place Figure 2 2 Mounting DIN Rail iServer 2 1 3 Removal from a DIN Rail a Insert flat screw driver into tab and...

Page 10: ...to OFF position it does not matter if the iServer is powered ON or OFF just make sure that the DIP switch is set to OFF otherwise every time the unit is power cycled the factory settings will take ov...

Page 11: ...at boot up they light up for 2 seconds then turn off DHCP if DHCP is enabled they blink and stay solid periodically POWER LED Green Solid Indicates Power ON for W model only DC Power Supply Section P...

Page 12: ...ssover cable with pin connection assignments are shown below Figure 2 5 10Base T Crossover Cable Wiring 2 5 Industrial Probe Choose one which gives the best signal integrity 1 Connect Probe s Shield t...

Page 13: ...ysical MAC address The MAC address can be found on the label of your device and contains 6 bytes 12 characters of hexadecimal numbers XX XX XX XX XX XX hex For example 0A 0C 3D 0B 0A 0B Remove the sma...

Page 14: ...ore enabling DHCP on the iServer The iServer is shipped with a default static IP address of 192 168 1 200 and Subnet Mask of 255 255 255 0 DIP switch 3 shown in ON position Figure 3 2 DIP Switch on iS...

Page 15: ...network or between two devices on the network There are three default TCP socket port numbers assigned to the iServer 1 Port 1000 when using HTTPget program see Section 4 5 2 Port 2000 when trying to...

Page 16: ...h configuring the iServer you can always set your PC back to its original settings On your computer from the MS DOS Prompt window type ping 192 168 1 200 and press Enter If DHCP and DNS servers are us...

Page 17: ...ent for obtaining an IP address Figure 4 2 Assigning an IP Address using iConnect 1 Place the IP address in this box 2 Take the MAC address from the label attached to the bottom of the iServer and pla...

Page 18: ...Server for Configuration Click on the View Webpage button you will access the iServer s home page refer to Section 4 3 for details Figure 4 3 Accessing the iServer s Home Page Menu iSERVER HOME PAGE R...

Page 19: ...the password First default LOGIN password is 12345678 and the ADMINISTRATOR password is 00000000 then you should be on the Access Control page were you can simply type in the desired Static IP addres...

Page 20: ...t access levels 1 ADMINISTRATOR Password administrator allows certain groups and individual users to access and modify entire iServer parameters without any restrictions The default password is 000000...

Page 21: ...ons If you do not have Java Runtime Environment you may download it from our website or contact the Customer Service Department nearest you Figure 4 7 Read Sensor 4 3 1 1 Java Runtime Environment 1 4...

Page 22: ...Sensor web page there may be a problem with access through a winsock proxy server In such cases your network administrator will need to provide the winsock proxy server and port s If the administrato...

Page 23: ...will only sense Temperature and Pressure to indicate this the Humidity and Dewpoint boxes on the chart will switch between OPEN and a false number TITLE Main Menu Title 1 Day Div 1 Day 1 Month 1 Week...

Page 24: ...Device Name Reading Offset Display Units Display Format Remote Format Remote End Char HEX 1 2 3 4 Temperature Pressure Humidity Dewpoint SRTF SRHb SRH2 SRDF2 F mbar F decimal decimal decimal decimal...

Page 25: ...s to read from the iServer simultaneously default is 5 Port default 2000 is the default TCP port number for the port to which the sensor is connected Ports 1000 used for HTTPget refer to Section 4 5 2...

Page 26: ...ure in C SRTF Read the temperature in F SRHb Read the pressure in mbar hPa SRHi Read the pressure in inHg Mercury SRHm Read the pressure in mmHg Mercury SRH2 Read the humidity SRDC2 Read the dewpoint...

Page 27: ...4 8mbar H37 9 D44 9F If the end character for instance is 20 Hex representation of space the data will then appear as T75 7F P1014 8mbar H37 9 D44 9F If nothing is set for the Remote End Char field th...

Page 28: ...er to Section 3 4 DNS MAC Address This is also called Hardware address or Ethernet address which is assigned to the iServer at production The MAC Media Access Control address is the iServer s unique h...

Page 29: ...e continuous data from the iServer In Command mode the command can be sent to query the iServer and get a response back Refer to Figure 3 3 4 5 HTTPget Program The HTTPget software is used to send a s...

Page 30: ...to the windows directory usually c winnt or c windows when installing the Mail Notifier software 1 Open up a command window or have a DOS window a Click on start menu b Click on Run c In the dialog b...

Page 31: ...ress 4 6 ARP Protocol ARP is the Internet layer protocol responsible for matching or obtaining the MAC hardware address that corresponds to a particular IP address The ARP command allows the user to v...

Page 32: ...ly from 192 168 1 96 bytes 32 time 5ms TTL 32 Reply from 192 168 1 96 bytes 32 time 3ms TTL 32 Reply from 192 168 1 96 bytes 32 time 3ms TTL 32 Reply from 192 168 1 96 bytes 32 time 4ms TTL 32 C arp a...

Page 33: ...ork rather than dedicated wiring The connected serial devices to iServer s can communicate with each other back and forth over the networks This characteristic is called Tunneling and it s illustrated...

Page 34: ...t option is used in Serial Tunneling and it applies only to the Local iServer If the tunneling connection between the two iServers goes down due to network problems power failure etc the Reconnect opt...

Page 35: ...ake place At this point reset the power first on the remote and then the local iServer and initialize the local serial device to send or request data Figure 4 17 Remote iServer Configuration Page No D...

Page 36: ...ware on a networked PC This software is compatible with Windows 95 98 NT 2000 XP and Vista c If you have Excel 2007 or higher when installing iLog choose Custom installation option and on the next win...

Page 37: ...HX SD 3 column iTHX W Dual Probe 1st probe 3 column 6 column iSE TC iSD TC 3 column 5 column iSE TH iSD TH 3 column 5 column iBTHX W iBTHX D 3 column 4 column iBTX W D iBTX M iBTX SD 2 column iPTX W 2...

Page 38: ...NT 4 0 2000 and XP in conjunction with existing email that supports the MAPI messaging interface If MS Outlook has been loaded the MAPI support should be available 4 9 1 Installation The Mail Notifie...

Page 39: ...be taken to enable the connection between the Mail Notifier and the Email server MS Outlook tends to require that the users respond to a login box in order for email access to be activated for Mail N...

Page 40: ...w value Specifying Pause Interval It determines how many seconds each subsequential alarm notification will be sent Determining Monitor interval It establishes the interval or time resolution in secon...

Page 41: ...40 to 41 F and 113 to 185 F Note extended temperature range is for Industrial Probe only the iServer s operating temperature is 0 to 70 C Response Time 5 to 30 seconds tau 63 Repeatability 0 1 C Reso...

Page 42: ...Input 100 to 240Vac 50 60 Hz included for iBTHX iBTX W Switching Power Supply Sold separately for iBTHX iBTX D Consumption 2 5 W max eNVIRoNmeNTAL Operating Temp 0 to 70 C 32 to 158 F Storage Temp 40...

Page 43: ...ons 2 60 66 0 1 08 27 4 3 67 93 1 0 25 6 4 0 25 6 4 1 78 45 2 2 42 61 6 3 56 90 3 0 14 3 6 0 30 7 7 3 05 77 5 3 55 90 2 0 93 23 6 0 82 20 8 0 88 22 4 Version A Version B COMMUNICATIONS ETHERNET DC POW...

Page 44: ...5 255 255 0 Device Host Name eis and last 4 digits from the MAC address Login Password 12345678 Admin Password 00000000 DHCP Disabled End Character 0D Hex Carridge Return Terminal Server Server Type C...

Page 45: ...number When you re connected to the Internet from your computer a correspondence table relates your IP address to your computer s physical MAC address on the LAN Ping is a utility that tests the netw...

Page 46: ...pport approximately 216 65 536 computers per network The IP addresses range in binary from 10000000 00000000 xxxxxxxx xxxxxxxx to 10111111 11111111 xxxxxxxx xxxxxxxx The IP addresses range in decimal...

Page 47: ...Mask Dotted Notation Mask Binary Mask Bits Class A 255 0 0 0 Default 0 255 192 0 0 2 255 224 0 0 3 255 240 0 0 4 255 248 0 0 5 255 252 0 0 6 255 254 0 0 7 255 255 0 0 8 255 255 128 0 9 255 255 192 0...

Page 48: ...01010010 DC3 19 13 00010011 S 83 53 01010011 DC4 20 14 00010100 T 84 54 01010100 NAK 21 15 00010101 U 85 55 01010101 SYN 22 16 00010110 V 86 56 01010110 ETB 23 17 00010111 W 87 57 01010111 CAN 24 18...

Page 49: ...17 11 Crtl Q Data Control 1 XON SOH 01 01 Crtl A Start of DC2 18 12 Crtl R Data Control 2 Header STX 02 02 Crtl B Start of Text DC3 19 13 Crtl S Data Control 3 XOFF ETX 03 03 Crtl C End of Text DC4 2...

Page 50: ...a request Wrong IP or wrong Port number was used 10011 Response came empty No data was sent 10012 Device responded with Possibly the iLog is configured for Serial Time Out string wrong product model...

Page 51: ...rage Conditions and Handling Instructions It is of great importance to understand that a humidity sensor is not a normal electronic component and needs to be handled with care Chemical vapors at high...

Page 52: ...sor Still if the sensor shares a PCB with electronic components that produce heat it should be mounted in a way that prevents heat transfer or keeps it as low as possible Furthermore there are self he...

Page 53: ...Transients Overvoltage Note The ac power adaptor must have Safety Qualified Agency Approvals for CE with Double Insulation rating The power input rating is 10 32Vdc The minimum output current rating...

Page 54: ..._________________________ ___________________________________________________________________________ ___________________________________________________________________________ ______________________...

Page 55: ..._________________________ ___________________________________________________________________________ ___________________________________________________________________________ ______________________...

Page 56: ...____________________________ ___________________________________________________________________________ ___________________________________________________________________________ ___________________...

Page 57: ...ONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications...

Page 58: ...ine Paddlewheel Systems R Totalizers Batch Controllers pH coNdUcTIVITY R pH Electrodes Testers Accessories R Benchtop Laboratory Meters R Controllers Calibrators Simulators Pumps R Industrial pH Condu...

Reviews: