background image

The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves 

the right to alter specifications without notice.

WARNING: These products are not designed for use in, and should not be used for, human applications.

Patented: Covered by U.S. and International Patents and Patents Pending. 

omega.com  [email protected] 

Omega Engineering, Inc: 

800 Connecticut Ave. Suite 5N01, Norwalk, CT 06854, USA 

Toll-Free: 1-800-826-6342 (USA & Canada only)  

C

 

ustomer Service: 1-800-622-2378 (USA & Canada only) 

Engineering Service: 1-800-872-9436 (USA & Canada only) 

Tel: (203) 359-1660 

e-mail: [email protected]

Fax: (203) 359-7700 

Omega Engineering, 

Limited: 

1 Omega Drive, Northbank, 

Irlam Manchester M44 5BD 

United Kingdom 

Omega Engineering, 

GmbH:  

Daimlerstrasse 26 75392 

Deckenpfronn Germany 

Summary of Contents for HX93B Series

Page 1: ...tters HX93B HX93BD WALL MOUNT HX93BD D DUCT MOUNT EASY M12 CONNECTION TH RP remote probe with 3 m 10 cable and M12 connector TM User sGuide Shop online at omega com e mail info omega com For the lates...

Page 2: ...y U S and International Patents and Patents Pending omega com info omega com Omega Engineering Inc 800 Connecticut Ave Suite 5N01 Norwalk CT 06854 USA Toll Free 1 800 826 6342 USA Canada only Customer...

Page 3: ...Measuring Range Selection 3 1 3 1 Electrical Connection 3 1 3 2 Temperature Measuring Range Selection 3 1 4 Mounting 4 1 5 Temperature Output Calculations 5 1 6 Relative Humidity Output Calculations...

Page 4: ...itter Internal Diagram 1 1 Figure 3 1 Electrical Connection Diagram 3 1 Figure 3 2 Temperature Measuring Range Selection Diagram 3 1 Figure 4 1 Wall Mount Model Dimensions 4 1 Figure 4 2 Duct Mount Mo...

Page 5: ...ith backlit to display both Temperature and Relative Humidity readings An on board slide switch allows the user to change the temperature reading from C to F as shown in figure 1 1 below Figure 1 1 Tr...

Page 6: ...he container and equipment for any signs of damage Note any evidence of rough handling in transit Immediately report any damage to the shipping agent The carrier will not honor any damage claims unles...

Page 7: ...ital Display Remote Probe Temperature Relative Humidity Transmitter 0 to 10 volt output with 3 m 10 cable HX93BC Wall Mount Temperature Relative Humidity Transmitter 4 to 20mA HX93BV0 Wall Mount Tempe...

Page 8: ...J4 The standard temperature measuring range is 30 to 75 C 22 to 167 F without adding any jumper on connector J4 If you would like to change the range to 20 to 75 C 4 to 167 F add a jumper on connecto...

Page 9: ...d for wall mounting and remote probe models A duct mounting kit is included with duct mount models See figure 4 1 figure 4 2 and figure 4 3 for the wall mount duct mount and remote probe model dimensi...

Page 10: ...obe Model Dimensions Mounting 4 4 2 82 3 3 24 48 3 1 90 27 9 1 1 17 3 0 68 FLEXIBLE CABLE 2 9 m 9 5 54 1 2 13 254 10 127 3 5 01 80 0 3 15 DIMENSIONS mm in 43 8 24 2 C RH 55 6 2 19 128 0 5 04 15 7 0 63...

Page 11: ...A 22 Offset temperature in F 0 0847 is the sensitivity which derived from the following Full scale current limit total temperature range 16 mA 189 F 0 0847mA F c To calculate temperature in C from a 0...

Page 12: ...owing Total out put voltage range out temperature range 5 0 v 189 F 0 0265 V F g To calculate temperature in C from a 0 to 10 volt output for the temperature range of 30 to 75 C Formula Temperature in...

Page 13: ...urrent measured in milliamps 4 0 16 Where 4 offset current in mA 0 16 Full scale current limit in percent For voltage output Formula RH voltage measured in volts x 100 a 1 volt output RH voltage measu...

Page 14: ...transmitter has been digitally calibrated and tested to meet or exceed the specifications outlined in this manual in our factory The transmitter must be sent back to the factory for any re calibration...

Page 15: ...filter if clogged may be removed for cleaning Unscrew the protective cover and gently blow compressed air through the filter screen A soft brush may also be used to remove dirt particles from the scr...

Page 16: ...100 Accuracy Range 2 5 from 20 to 80 RH 3 5 from 5 to 20 and 80 to 95 RH 4 from 0 to 5 and 95 to 100 RH Hysteresis 1 Repeatability 0 1 Resolution 0 1 Response Time 8 Seconds typical Sample Rate 1 Sam...

Page 17: ...pts 14 to 22 gauge wire Dimensions See Mounting Section Weight HX93B 151 g 8 9 oz HX93B D 256 g 9 0 oz HX93B RP1 352 g 12 4 oz Display HX93BD Series only Indicator Two 4 digit digital back lit LCD Dis...

Page 18: ...A if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to m...

Page 19: ...s M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U...