Section 9 - Specifications
TEMPERATURE
Measuring Range
Standard:
-30 to 75ºC (-22 ºF to 167ºF) without jumper on
connector J4
Special:
-20 to 75°C (-4 to 167°F) with jumper added on
connector J4 pin 1 to 2. See figure 3-2.
Accuracy:
±0.6ºC from 0 to 50ºC (32 to 122ºF),
±1.25ºC from - 30 to 0ºC (-22 to 32ºF) and
50 to 75ºC (122 to 167ºF)
Repeatability:
±0.2ºC (0.4ºF)
Resolution:
0.1ºC
Response Time:
5 Seconds min., 30 seconds max.
Sample Rate:
1 Sample every 4 seconds
RELATIVE HUMIDITY
Measuring Range:
0 to 100%
Accuracy Range:
±2.5 % from 20 to 80% RH, ±3.5% from 5 to 20%
and 80 to 95% RH, ±4% from 0 to 5% and 95 to
100% RH
Hysteresis:
±1%
Repeatability:
±0.1%
Resolution:
0.1%
Response Time:
8 Seconds typical
Sample Rate:
1 Sample every 4 seconds
Operating Temperature Range: -30 to 75ºC
Input Power:
9 to 30 Vdc @ 100mA:
4 to 20mA, 0-1 volt, 0-5 volt output
12 to 30 Vdc @ 100mA:
0 to 10 volts output
Max Loop Resistance:
200 Ohms @ 9 Vdc supply voltage
(4 to 20 mA Output)
1,250 Ohms @ 30 Vdc supply
voltage Ohms = [(V supply - 4V) /0.02A)] -50
Max. Load Resistance:
1.25 K (For all outputs: 0-1 Vdc, 0-5 Vdc,
(min. resistance)
0-10 Vdc)
Sensor Type:
Digital Sensor
Enclosure Housing:
Gray Polycarbonate,
NEMA 13 (IP54)
9-1
Specifications
9